![GEM SUPM SUMONDO Operating Instructions Manual Download Page 5](http://html1.mh-extra.com/html/gem/supm-sumondo/supm-sumondo_operating-instructions-manual_2206359005.webp)
www.gemu-group.com
5 / 37
GEMÜ SUPM
2 Safety information
The safety information in this document refers only to an indi-
vidual product. Potentially dangerous conditions can arise in
combination with other plant components, which need to be
considered on the basis of a risk analysis. The operator is re-
sponsible for the production of the risk analysis and for com-
pliance with the resulting precautionary measures and re-
gional safety regulations.
The document contains fundamental safety information that
must be observed during commissioning, operation and main-
tenance. Non-compliance with these instructions may cause:
–
Personal hazard due to electrical, mechanical and
chemical effects.
–
Hazard to nearby equipment.
–
Failure of important functions.
–
Hazard to the environment due to the leakage of dan-
gerous materials.
The safety information does not take into account:
–
Unexpected incidents and events, which may occur
during installation, operation and maintenance.
–
Local safety regulations which must be adhered to by
the operator and by any additional installation person-
nel.
Prior to commissioning:
1. Transport and store the product correctly.
2. Do not paint the bolts and plastic parts of the product.
3. Carry out installation and commissioning using trained
personnel.
4. Provide adequate training for installation and operating
personnel.
5. Ensure that the contents of the document have been fully
understood by the responsible personnel.
6. Define the areas of responsibility.
7. Observe the safety data sheets.
8. Observe the safety regulations for the media used.
During operation:
9. Keep this document available at the place of use.
10. Observe the safety information.
11. Operate the product in accordance with this document.
12. Operate the product in accordance with the specifications.
13. Maintain the product correctly.
14. Do not carry out any maintenance work and repairs not de-
scribed in this document without consulting the manufac-
turer first.
In cases of uncertainty:
15. Consult the nearest GEMÜ sales office.
3 Product description
3.1 Construction
1
2
3
4
5
6
7
8
9
10
11
Item
Name
Materials
1
Optical position indicator
1.4305
2
Piston
1.4571
3
Valve spindle
1.4571
4
Actuator
1.4408
5
Mounting plate
1.4404
6
Indexing plunger
PA6
7
Tri-clamp
1.4401
8
Valve body
PP-R
9
Diaphragm
TPE
10 Diaphragm pin
PP-R
11 Distance piece
1.4435
3.2 Description
The single-use diaphragm valve body of the GEMÜ SUMONDO
single-use diaphragm valve has a hermetic sealing through an
internally welded diaphragm. For installation, the single-use
diaphragm valve body is secured on the pneumatic stainless
steel actuator or on the manual actuator and is locked using
locking pins. After use, the single-use diaphragm valve body
can be removed from the actuator along with the diaphragm
and disposed of. The actuators can be used multiple times.
3.3 Function
The GEMÜ single-use diaphragm valve, consisting of the SUB
single-use diaphragm valve body and the SUPM pneumatic
stainless steel actuator, is designed for installation in single-
use systems in plastic pipe and hose lines. It controls a flow-
ing medium by being closed or opened by a control medium.
3 Product description