5
www.systemq.com
Camera Setup
The cameras
Baud Rate
,
ID
and
Terminal Resistor
are all controlled using dip switches located on the
underside of the dome, above the lens.
Unscrew the two screws and remove the clear plastic
cover to gain access to the dip switches. There are
to sets of dip switches.
SW1
is used to configure the
camera’s ID. While
SW2
is used to configure the
camera’s baud rate and terminal resistor.
ID Setup
The camera’s ID (Address) is configured using the
SW1 set of eight dip switches. SW1 uses a binary
system where switch 1 represents the number 1,
through to switch 8 representing the number 128. Each
PTZ on a system must have its on unique ID. Examples
of how to set the camera’s ID are shown on the right.
PTZ number 1
PTZ number 3
PTZ number 5
PTZ number 7
PTZ number 254
PTZ number 8
PTZ number 255
PTZ number 6
PTZ number 4
PTZ number 2