12.4.9 Product ID
The product ID can be read out in ASCII format with the
Product ID
parameter.
Index Sub-
Index
Off-
set
Access
Rights
Length
Index name
Parameter
Type
Values
0x13
0
0
RO
14 bytes
Product ID
StringT
"eSyStep On/Off"
12.4.10 Serial number
The serial number of the device can be read out with the
Serial number
parameter.
The serial number consists of an 8-digit completion confirmation number, a forward slash and a 4-digit index.
Index Sub-
Index
Off-
set
Access
Rights
Length
Index name
Parameter
Type
Values
0x15
0
0
RO
13 bytes
Serial number
StringT
"XXXXXXXX/YYYY"
12.4.11 Hardware revision
The circuit boards' version can be read out with the
Hardware revision
parameter.
The hardware version is displayed with the 2-digit version number of the basic assembly and the 2-digit version number of the
OPEN/CLOSED or positioner assembly.
Index Sub-
Index
Off-
set
Access
Rights
Length
Index name
Parameter
Type
Values
0x16
0
0
RO
10 bytes
Hardware revision
StringT
"Rev. XX/XX"
12.4.12 Firmware revision
The software version can be read out with the
Firmware revision
parameter.
Index Sub-
Index
Off-
set
Access
Rights
Length
Index name
Parameter
Type
Values
0x17
0
0
RO
9 bytes
Firmware revision
StringT
"V X.X.X.X"
12.4.13 Application specific tag
A text with 32 characters can be stored in the device with the
Application specific tag
parameter.
For example, installation location, function, installation date, etc.
Index Sub-
Index
Off-
set
Access
Rights
Length
Index name
Parameter
Type
Values
0x18
0
0
R/W
32 bytes
Application
specific tag
StringT
„**************** "
GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
www.gemu-group.com
47 / 71
12 Specific data IO-Link (pin 6)