18 Troubleshooting / Fault clearance
Fault
Possible cause
Fault clearance
Control medium escapes from connector 4*
(control function NC) or from connector 2*
(control function NO)
(see chapter 11.3 "Control functions")
Piston lip ring leaking
Replace valve
Control medium escapes from leak detection
port* (only for control function NC)
Lower spindle lip ring leaking
Replace valve and check control
medium for impurities
Working medium escapes from leak detection
port*
Diaphragm faulty
Replace valve
Valve doesn't open or doesn't open fully
Control pressure too low
(for control function NC)
Operate valve with control
pressure specified in data sheet
Pilot valve faulty
Check pilot valve and replace
Control medium not connected
Connect control medium
Lower spindle lip ring or piston lip
ring leaking
Replace valve
Stroke limiter** incorrectly set
Correctly adjust stroke limiter
Actuator spring faulty
(for control function NO)
Replace valve
Valve leaks downstream
(doesn't close or doesn't close fully)
Operating pressure too high
Operate valve with operating
pressure specified in data sheet
Control pressure too low
(for control function NO
and for control function DA)
Operate valve with control
pressure specified in data sheet
Foreign matter between
diaphragm and valve body weir
Replace valve
Valve body weir damaged
Replace valve
Diaphragm faulty
Replace valve
Actuator spring faulty
(for control function NC)
Replace valve
Valve body connection to piping leaks
Incorrect installation
Check installation of valve body
in piping
Union nuts loose
Tighten union nuts
Control medium escapes from transparent
cap** (for control function NO and for control
function DA)
Upper spindle lip ring leaking
Replace valve
* see chapter 10 "Construction"
** see chapter 11.5 "Setting the stroke limiter"
43 / 48