6.6 Duty cycle and service life
Service life:
Control operation
- Class C acc. to EN 15714-2 (1,800,000 start-ups and 1200 start-ups per hour).
Open / Close duty
- Minimum 1,000,000 switching cycles at room temperature and permissible
duty cycle.
Duty cycle:
Control operation
- Class C acc. to EN 15714-2.
Open/Close duty
- 100% ED.
6.7 Electrical data
Supply voltage:
Actuator size 0
Actuator size 1
Actuator size 2
Voltage
Uv = 24 V DC ± 10%
Rating
Max. 28 W
Max. 65 W
Max. 120 W
Reverse battery protec-
tion
Yes
6.7.1 Analogue input signals
6.7.1.1 Set value
Input signal:
0/4 - 20 mA; 0 – 10 V DC (selectable using software)
Input type:
passive
Input resistance:
250 Ω
Accuracy/linearity:
≤ ±0.3% of full flow
Temperature drift:
≤ ±0.1% / 10°K
Resolution:
12 bit
Reverse battery protec-
tion:
No
Overload proof:
Yes (up to ± 24 V DC)
6.7.1.2 Process actual value
Input signal:
0/4 - 20 mA; 0 – 10 V DC (selectable using software)
Input type:
passive
Input resistance:
250 Ω
Accuracy/linearity:
≤ ±0.3% of full flow
Temperature drift:
≤ ±0.1% / 10°K
Resolution:
12 bit
Reverse battery protec-
tion:
No
Overload proof:
Yes (up to ± 24 V DC)