7.5 Mechanical data
Protection class:
IP 65 acc. to EN 60529
Actuating speed:
Max. 3 mm/s
Installation position:
Optional
Weight:
Actuator
DN
Actuator
size
Weight
without valve body
15
1A
1.20
20
1A
1.21
25
1A
1.22
32
1A
1.48
32
3A
2.10
40
1A
1.75
40
3A
2.25
50
1A
2.00
50
3A
2.50
Weights in kg
Valve body
DN
Weight
15
2.2
20
3.0
25
3.7
32
5.3
40
6.3
50
8.4
Weights in kg
Mechanical environ-
mental conditions:
Class 4M8 acc. to EN 60721-3-4:1998
Vibration:
5g acc. to IEC 60068-2-6 Test Fc
Shock:
25g acc. to 60068-2-27 Test Ea
7.6 Duty cycle and service life
Service life:
Class A acc. to EN 15714-2
Minimum 100,000 switching cycles at room temperature and permissible duty cycle.
Duty cycle:
max. 30% duty
GEMÜ 519 eSyLite
www.gemu-group.com
11 / 29