background image

www.gemu-group.com

17 / 20

GEMÜ 0326

14 Inspection and maintenance

 WARNING

The equipment is subject to pressure!

Risk of severe injury or death.

Depressurize the plant.

Completely drain the plant.

 WARNING

Danger of burning from hot surfaces!

Solenoid coil heats up during opera-

tion.

Allow the solenoid coil and piping to

cool down before servicing work.

 CAUTION

Servicing and maintenance work must only be performed

by trained personnel.

GEMÜ shall assume no liability whatsoever for damage

caused by improper handling or third-party actions.

In case of doubt, contact GEMÜ prior to commissioning.

1. Use appropriate protective gear as specified in plant oper-

ator's guidelines.

2. Shut off plant or plant component.
3. Secure against recommissioning.
4. Depressurize the plant or plant component.

NOTICE

Only use genuine GEMÜ spare parts.

When ordering spare parts, please state the complete or-

der number of the pilot solenoid valve.

The operator must carry out regular visual examination of the

valves dependent on the operating conditions and the poten-

tial danger in order to prevent leakage and damage. The valve

also has to be checked for wear in the corresponding inter-

vals.

15 Disassembly

Disassembly is performed observing the same precautionary

measures as for installation.
1. Disassemble the pilot solenoid valve (see "Installation").
2. Disconnect the electric wire(s) (see "Electrical connec-

tion").

16 Disposal

1. Pay attention to adhered residual material and gas diffu-

sion from penetrated media.

2. Dispose of all parts in accordance with the disposal regu-

lations/environmental protection laws.

17 Returns

Legal regulations for the protection of the environment and

personnel require that the completed and signed return deliv-

ery note is included with the dispatch documents. Returned

goods can be processed only when this note is completed. If

no return delivery note is included with the product, GEMÜ

cannot process credits or repair work but will dispose of the

goods at the operator's expense.
1. Clean the product.
2. Request a return delivery note from GEMÜ.
3. Complete the return delivery note.
4. Send the product with a completed return delivery note to

GEMÜ.

17 Returns

Summary of Contents for 0326

Page 1: ...GEM 0326 Electrically operated pilot solenoid valve Operating instructions EN further information webcode GW 0326...

Page 2: ...rights including copyrights or industrial property rights are expressly reserved Keep the document for future reference GEM Gebr M ller Apparatebau GmbH Co KG 30 06 2021 www gemu group com 2 20 GEM 0...

Page 3: ...Transport 12 9 3 Storage 12 10 Installation 12 11 Electrical connection 13 11 1 Plug design A 14 11 2 M12 plug code 02 03 15 11 3 Manual override option 15 12 Commissioning 15 13 Troubleshooting 16 1...

Page 4: ...flows through the GEM product 1 4 Warning notes Wherever possible warning notes are organised according to the following scheme SIGNAL WORD Type and source of the danger Possible symbol for the specif...

Page 5: ...stood by the responsible personnel 6 Define the areas of responsibility 7 Observe the safety data sheets 8 Observe the safety regulations for the media used During operation 9 Keep this document avail...

Page 6: ...near the pneumatic components to be controlled The body is made of plastic The coil is plastic encapsulated 5 1 Product without ATEX code 06 08 09 The product is not intended for use in potentially e...

Page 7: ...reen LED suppression diode only for 24V DC version 09 10 Option Code Without 00 10 Continuation of Option Code ATEX only electrical connection 05 only control function normally closed 01 Manual overri...

Page 8: ...Connection for GEM battery rail 5 Valve body solenoid material 74 PA polyamide 6 Seal material 4 FPM 7 Control function 1 Normally closed NC 8 Voltage Frequency C1 24 V DC 9 Electrical connection 01...

Page 9: ...Operating pressure 0 10 bar Flow rate Control function Normally closed code 1 70 l min Normally open code 2 40 l min 7 4 Product compliance Explosion protection ATEX 2014 34 EU order code Option ATEX...

Page 10: ...0580 Duty cycle Continuous duty Max perm ripple 20 Electrical connection type Plug design A Cable diameter 8 to 10 mm Optional M12 plug cable socket Optional ATEX version with 3 m cable H05V2V2 F 3G1...

Page 11: ...5 30 40 5 4 2 G1 4 81 5 20 25 52 77 49 8 12 5 M4 Z Number of valve seats valves maximum 10 valves possible Female thread M4 for the connection of the potential equalisation acc to ATEX Blanking plate...

Page 12: ...lve prior to the installation See chapter Technical data 10 1 Installation WARNING The equipment is subject to pressure Risk of severe injury or death Depressurize the plant Completely drain the plant...

Page 13: ...ction DANGER Risk of electric shock Risk of injury or death if operating voltage is higher than safe extra low voltage Electric shock can cause severe burns and fatal injury Work on electrical connect...

Page 14: ...Screw plug 2 to solenoid with retaining screw 1 max 0 3 Nm 11 Close cable entry 6 Fig 3 Rear of terminal block Item Name 1 Supply voltage 2 Supply voltage 3 Not connected Earth 11 1 Plug design A 11 1...

Page 15: ...Manual override option Fig 4 Manual override The pilot solenoid valves are equipped with a manual override as an option Only actuate the manual override in case of malfunction To activate lock the ma...

Page 16: ...pilot solenoid valve doesn t close or doesn t close fully Return spring faulty Replace the pilot solenoid valve Dirt in the valve body Clean or replace valve body Manual override activated Unlock the...

Page 17: ...valves dependent on the operating conditions and the poten tial danger in order to prevent leakage and damage The valve also has to be checked for wear in the corresponding inter vals 15 Disassembly D...

Page 18: ...ve We GEM Gebr M ller Apparatebau GmbH Co KG Fritz M ller Stra e 6 8 74653 Ingelfingen Criesbach Germany declare that the product listed below complies with the directives named above Description of t...

Page 19: ...sion protection designation Gas II 2G Ex mb II T4 Dust II 2D Ex tD A21 IP65 T130 C Type examination certificate PTB 03 ATEX 2018 X Explanations For special conditions or operation limits see chapter C...

Page 20: ...GEM Gebr M ller Apparatebau GmbH Co KG Fritz M ller Stra e 6 8 74653 Ingelfingen Criesbach Germany Phone 49 0 7940 1230 info gemue de www gemu group com Subject to alteration 06 2021 88660085 88660085...

Reviews: