background image

2

Gerhard Geiger GmbH & Co. KG | 100W1502

0519

V000

en

EN

EN

Index

1.  General information .........................................................3
2.  Guarantee ..........................................................................3
3.  Safety information ............................................................3
4.  Intended use .....................................................................4
5.  Installation instructions ...................................................5
6.  Setting of the end stops ...................................................6
7.  Declaration of conformity ................................................7
8.  Information for the specialist electrician .......................7
9.  Notes on waste disposal .................................................7
10. What to do if… ..................................................................8

Technical data

Technical data tubular motor SOLIDline-MOR (GU45..)

GU4510

GU4520

GU4530

GU4540

GU4550

Voltage

230 V~/50 Hz

Current 

0,47 A

0,63 A

0,8 A

1,0 A

1,0 A

Cos Phi (cos

j

)

>0,95

Inrush current (factor)

x 1,2

Power

105 W

140 W

180 W

220 W

220 W

Torque 

10 Nm

20 Nm

30 Nm

40 Nm

50 Nm

Speed of rotation 

16 1/min

16 1/min

16 1/min

16 1/min

12 1/min

Protection type 

IP 44

Total length 

611 mm

641 mm

661 mm

681 mm

681 mm

Operating type

S2 4 min

S2 5 min

S2 4 min

S2 4 min

S2 4 min

Diameter

45 mm

Limit switch range

22 rotations

Crank reduction

24:1

Weight

approx.  

 3,10 kg

approx.  

 3,40 kg

approx.  

 3,60 kg

approx.  

 3,90 kg

approx.  

 3,90 kg

Storage temperature/
Humidity

T = -15°C .. +70°C / dry and non-condensing place

Subject to technical modifications. Please find information to the ambient  

temperature range of our GEIGER motors under www.geiger.de 

 

      

Summary of Contents for SOLIDline-MOR GU4510

Page 1: ...r de EN EN DE EN FR IT Bedienungsanleitung Operating Instructions Manuel d utilisation Istruzioni per l uso Tubular motor GEIGER SOLIDline MOR Motor control GEIGER Spindle for rolling shutters awnings and screens ...

Page 2: ...A 1 0 A Cos Phi cosj 0 95 Inrush current factor x 1 2 Power 105 W 140 W 180 W 220 W 220 W Torque 10 Nm 20 Nm 30 Nm 40 Nm 50 Nm Speed of rotation 16 1 min 16 1 min 16 1 min 16 1 min 12 1 min Protection type IP 44 Total length 611 mm 641 mm 661 mm 681 mm 681 mm Operating type S2 4 min S2 5 min S2 4 min S2 4 min S2 4 min Diameter 45 mm Limit switch range 22 rotations Crank reduction 24 1 Weight appro...

Page 3: ...hysical sensorial or mental capacities are impaired or who have no expe rience or know how unless they have been supervised or been given instructions on the use of the appliance by someone who is responsible for their safety f f Children must be supervised to make sure they do not play with the appliance f f The installation is to be checked regularly for defective balance wear and damage f f Dam...

Page 4: ... must be at least 1 5 m above the floor If the apparatus is equipped without a pin and a socket connector STAS3K in the connecting lead or other means for disconnecting from the mains with at least a 3 mm contact opening on each pole a disconnecting device of this type must be incorporated into the permanently installed electrical installation according to the wiring rules f f Permanently installe...

Page 5: ...ion M45F397 Insert the motor into the shaft with a suitable adapter drive up to the stop of the shaft adapter Insert the roller capsule on the opposite side Screw the square fixation M45F396 with the motor head On the opposite side pull out the roller capsule until the bolt fits into the ball bearing Screw together the roller capsule with the shaft Screw together the shaft with the tube drive Secu...

Page 6: ... the DOWN key until the hanging is below the selected end position Turn the setting screw a few turns in the direction opposite the PLUS direction and repeat the above procedure again Setting the lower end position Press the DOWN key until the hanging automati cally stops Depending on the installation turn the corresponding setting screw while pressing the DOWN key in PLUS direction until the sele...

Page 7: ...hanging the running direction the switchover must be effected through an off position When changing the running direction the switchover time must be at least 0 5 s Connecting cables with plug connectors of the Hirschmann Company type STAS 3K may only be used in connection with the Hirschmann cable socket STAK 3K 9 Notes on waste disposal Recycling of packaging materials In the interest of environ...

Page 8: ...oltage and allow the cause of the voltage break down to be tested by a specialist electrician Instead of in the upwards direction motor runs downwards The control leads are interchanged Exchange black brown control leads Motor only runs in one direction Motor in the end position Run motor in the opposite direction After running several times the motor breaks down and no longer responds The motor b...