9
9 Technical characteristics
Supply voltage
230 VAC (+/- 10 %), 50 Hz
Length of connecting cables
Power cable: 400 mm incl. wire-end sleeves
Motor connection cable: 100 mm incl. wire-end
sleeves
Active power consumption of the control
approx. 0.4 W
Relay switching current (resistive)
5A
Degree of protection
IP54
Motor run time
Towards "retracting": 140 s + 15 s reserve
(respond time of the UP / DOWN relay)
"extending": 140 s
Intermediate position
Times within a range from 5 up to 140 seconds
learnable (ex end position "retracted")
"Learning" standby after power ON
10 min.
Lock wait time "wind"
10 min.
Lock wait time "rain"
10 min.
Lock wait time "service"
5 min.
Timer function in automatic mode
240 minutes after the system has last
(command for running in (retracting)
been operated manually
in the case of a "sun dark" event