9 Technical characteristics

Supply voltage

230 VAC (+/- 10 %), 50 Hz

Length of connecting cables

Power cable: 400 mm incl. wire-end sleeves

Motor connection cable: 100 mm incl. wire-end 

sleeves

Active power consumption of the control

approx. 0.4 W

Relay switching current (resistive)

5A

Degree of protection

IP54

Motor run time

Towards "retracting": 140 s + 15 s reserve

(respond time of the UP / DOWN relay)

"extending": 140 s

Intermediate position

Times within a range from 5 up to 140 seconds 

learnable (ex end position "retracted")

"Learning" standby after power ON

10 min.

Lock wait time "wind"

10 min.

Lock wait time "rain"

10 min.

Lock wait time "service"

5 min.

Timer function in automatic mode

240 minutes after the system has last

(command for running in (retracting)

been operated manually

in the case of a "sun dark" event

10 Declaration of Conformity

We hereby state and declare that the device described herein complies with the basic requirements and

relevant prescriptions established and laid down in the EC directive 1999/5/EG and that it is licensed for

use in all member states of the EU and in Switzerland without any need of prior registration.
To learn more about the Declaration of Conformity pertaining to this device, please visit our website at:

www.geiger.de

Summary of Contents for GFM001

Page 1: ...EN Awning control system for 230V drives for pre coded systems GFM001 Installation and operating instructions...

Page 2: ...Extensions and individual settings 6 7 1 Learning of radio commands 6 7 2 Coding set in the condition as delivered 6 7 3 Learning of the coding of a hand held transmitter 6 7 4 Learning of a sensor 7...

Page 3: ...modifications to the control system will result in the invalidity of all warranty claims Immediately after its unpacking the control system must be checked for damages The device must in case damages...

Page 4: ...nter key Actuating the counter key stops the approx 0 5 to 1 5 seconds travelling motion immediately Repeated actuation The travelling operation is in travel direction continued without interruption O...

Page 5: ...ffects that the awning is extended over the term of the remaining runtime Any actuation of the key UP Auf after the attaining of intermediate stop position effects that the awning is retracted over th...

Page 6: ...hand coding condition as delivered If several control systems are to be installed that shall be operated individually each radio receiver must get its individual coding This can be realised by changi...

Page 7: ...s purpose Learned intermediate positions can for extending purposes be displaced at any time on the aforementioned timeline To learn an intermediate position proceed as follows 1 Use the related trans...

Page 8: ...conds another audible signal resounds long tone 4 Immediately let the key EIN ON go again when hearing the long tone 5 All values stored beforehand have been cancelled and the control operates in norm...

Page 9: ...ndby after power ON 10 min Lock wait time wind 10 min Lock wait time rain 10 min Lock wait time service 5 min Timer function in automatic mode 240 minutes after the system has last command for running...

Page 10: ...N For technical questions please call our service team at 49 0 7142 938 333 They will be happy to assist you Gerhard Geiger GmbH Co KG Schleifm hle 6 D 74321 Bietigheim Bissingen T 49 0 7142 9380 F 49...

Reviews: