4.2  Safe Operation

Comply  with  the  requirements  of  accident  prevention  regulation  “Processing  of  Coating

Materials” (e.g. in Germany VBG 23).

All persons using the

ABAC

 Motor Blower must have read and understood this Operating

Manual, particularly the section entitled “Safety Notes”.

The

ABAC

 SG 90 E Motor Blower is not of flame-proof design. Take care to ensure that

there are no ignition sources in the vicinity, such as naked flames, sparks, glowing wires,

hot  surfaces,  lighted  cigarettes  etc.  The  distance  between  spray  jet  exit  and  a  possible

source of ignition (even the Blower itself) must be at least 5 m (fire and explosion hazard

from ignitable spray mist).

It  must  not  be used  in  works  locations  subject  to  the provisions of  explosion  prevention

regulation, or on premises and in areas where there is a risk of fire.

Use only paints and solvents with a flash point of 21

°

C/70

°

F or higher without additional

heating (see details on paint tin).

When  working  in  confined  spaces,  these  must  be  properly  ventilated  using  effective

technical ventilation systems.

The sprayed paint emerges from the nozzle at high pressure. Never direct the spray jet at

people  or  animals.  If  the  skin  is  injured  by  paint,  lacquer  or  solvent  there  is  a  risk  of

infection. Seek medical treatment immediately and tell the doctor which paint, lacquer or

solvent was used.

Poisonous  fumes  may  be  given  off  during  spraying  (see  paint  tin  for  details).  Use  a

breathing mask as directed by paint manufacturer’s instructions. Keep children and other

people away from the working area.

The

ABAC

 SG 90 E Motor Blower is not splash-proof. It must not be used out of doors,

when it is raining or splashed or washed with water or immersed in liquid.

Keep  the

ABAC

  SG  90  E  Motor  Blower  in  a  safe  place  that  is  inaccessible  to  children

and  unauthorized  personnel.  Make  sure  that  no  unauthorized  personnel  (particularly

children) can put the

ABAC

 SG 90 E Motor Blower into operation.

Store your Motor Blower in a dry ventilated room.

For  safety  reasons  you  should  only  use

ABAC

  original  accessories  and

ABAC

  original

spare parts.

Summary of Contents for ABAC SG 90 E

Page 1: ...Geheit GmbH Benzstra e 2 D 72636 Frickenhausen Germany Phone 49 0 7022 78969021 Fax 49 0 7022 78969029 www shop geheit de Motor Blower SG 90 E Operating Manual...

Page 2: ...as aplicadas Normas harmonizadas aplicadas Norme armonizate aplicate Zastosowane normy zharmonizowane Pielietotie harmoniz tie standarti Kohaldatud harmoniseeritud normid Taikyti darnieji standartai P...

Page 3: ...are Maintenance and Repair 10 8 1 Replacing Intake Filter 11 9 Faults Possible Causes and Remedies 12 10 Operating Instructions 13 11 Spare Parts 13 2019 by Geheit GmbH Printed in Germany All rights r...

Page 4: ...s BJ 370 000 0021 100 V BJ 370 000 0041 115 V BJ 370 000 0002 230 V Always observe and comply with all processing instructions and safety notes provided by material manufacturers as well the prescript...

Page 5: ...e Motor Blower is self cooled which means that working air sucked from the atmosphere is also used to cool the motor If any blocking at discharge appears and exists for some time the unit will be over...

Page 6: ...V 1 N 50 60 Hz AC 115 V 1 N 50 60 Hz AC 230 V 1 N 50 60 Hz o Insulation Protection Class II o Power 1130 W o Power consumption approx 10 2 A 100 V approx 10 2 A 115 V approx 5 6 A 230 V o Speed 25 00...

Page 7: ...y for use with our own PN 2 or PN 5 ABAC low pressure spray guns which operate in the low pressure range up to 0 45 bar You must also follow the instructions given in the relevant operating manuals fo...

Page 8: ...tin When working in confined spaces these must be properly ventilated using effective technical ventilation systems The sprayed paint emerges from the nozzle at high pressure Never direct the spray je...

Page 9: ...to spray in the direction of your Motor Blower Dispose of your cleaning and spraying material wastes according to the instructions given by the relevant lacquer paint and solvent manufacturers The ai...

Page 10: ...is from 0 to 45 relative humidity must not exceed 80 Attention Use for transport only the handle of the Motor Blower Never attempt to move the Blower by pulling on its air hose or electric cable Use o...

Page 11: ...voltage indicated on the rating plate or in this Operating Manual Connect the air hose to the Blower by turning the air hose connector clockwise in the blower opening fig 4 6 2 Switching on and Adjust...

Page 12: ...s or borders of the object to be sprayed are properly masked 7 Switching off the Motor Blower After you have finished spraying turn off the Blower by pressing the push button with your thumb Only then...

Page 13: ...lter cap Always replace the intake filter when it is dirty Do not attempt to clean it The intake filter should always be checked before spraying and replaced when dirty as shown in figure 7 This ensur...

Page 14: ...Motor Blower delivers too much or too little air Rotary knob incorrectly set Reset rotary knob such that required air quantity is delivered Motor Blower will not run No mains voltage Check mains conne...

Page 15: ...all employees 11 Spare Parts For safety reasons you should only use ABAC original accessories and ABAC original spare parts Spare parts are available from your ABAC specialist dealer or directly from...

Reviews: