background image

5

4

Safety Notes

Besides  this  Operating  Manual  and  the  statutory  safety  regulations  for  accident  prevention

applicable in the country and place of use, operators must also abide by the recognized codes

of practice for safe and workmanlike operation.

4.1

Principles; Correct Operation

The  Motor  Blower  is  state  of  the  art  equipment  complying  with  recognized  safety

regulations.  However,  if  used  improperly  there  is  a  risk  of death or  injury  to  the user or

other persons, or of damage to the machine or other property.

The Motor Blower should only be used for its intended purpose and when it is in a perfect

working order. The user must be safety conscious, fully aware of the risk, and follow the

operating  instructions.  Faults  that  could  impair  the  operating  safety  of  the  unit  must  be

immediately remedied by an authorized person.

The SG 90 E Motor Blower is intended solely for use with our own PN 2 or PN 5

ABAC

low-pressure  spray  guns,  which  operate  in  the  low-pressure  range  up  to  0,45  bar.  You

must also follow the instructions given in the relevant operating manuals for these

ABAC

low-pressure spray guns PN 2 and PN 5.

It  should  not  be  used  together  with  low-pressure  spray  guns  with  intermittent  air

supply (such as ABAC PN 1 / PN 1A Spray Guns)!

It  must  not  be  used  for  any  other  purpose.  The  manufacturer  or  supplier  is  not

responsible and will not be liable for damage or injury resulting from improper use, which

shall be entirely at the user’s risk.

Warranty  obligations  are  valid  only  if  the  user  observes  the  instructions  and

recommendations described in this operating manual.

Unauthorized changes and repair,

use for maintenance of spare parts other than original parts supplied with the product and

approved by the manufacturer or included in the spare parts list, as well operation of the

equipment  under  conditions  other  than  those  permitted  in  this  manual,  will  void  the

manufacturer’s guarantee for the

ABAC

 SG 90 E Motor Blower.

Summary of Contents for ABAC SG 90 E

Page 1: ...Geheit GmbH Benzstra e 2 D 72636 Frickenhausen Germany Phone 49 0 7022 78969021 Fax 49 0 7022 78969029 www shop geheit de Motor Blower SG 90 E Operating Manual...

Page 2: ...as aplicadas Normas harmonizadas aplicadas Norme armonizate aplicate Zastosowane normy zharmonizowane Pielietotie harmoniz tie standarti Kohaldatud harmoniseeritud normid Taikyti darnieji standartai P...

Page 3: ...are Maintenance and Repair 10 8 1 Replacing Intake Filter 11 9 Faults Possible Causes and Remedies 12 10 Operating Instructions 13 11 Spare Parts 13 2019 by Geheit GmbH Printed in Germany All rights r...

Page 4: ...s BJ 370 000 0021 100 V BJ 370 000 0041 115 V BJ 370 000 0002 230 V Always observe and comply with all processing instructions and safety notes provided by material manufacturers as well the prescript...

Page 5: ...e Motor Blower is self cooled which means that working air sucked from the atmosphere is also used to cool the motor If any blocking at discharge appears and exists for some time the unit will be over...

Page 6: ...V 1 N 50 60 Hz AC 115 V 1 N 50 60 Hz AC 230 V 1 N 50 60 Hz o Insulation Protection Class II o Power 1130 W o Power consumption approx 10 2 A 100 V approx 10 2 A 115 V approx 5 6 A 230 V o Speed 25 00...

Page 7: ...y for use with our own PN 2 or PN 5 ABAC low pressure spray guns which operate in the low pressure range up to 0 45 bar You must also follow the instructions given in the relevant operating manuals fo...

Page 8: ...tin When working in confined spaces these must be properly ventilated using effective technical ventilation systems The sprayed paint emerges from the nozzle at high pressure Never direct the spray je...

Page 9: ...to spray in the direction of your Motor Blower Dispose of your cleaning and spraying material wastes according to the instructions given by the relevant lacquer paint and solvent manufacturers The ai...

Page 10: ...is from 0 to 45 relative humidity must not exceed 80 Attention Use for transport only the handle of the Motor Blower Never attempt to move the Blower by pulling on its air hose or electric cable Use o...

Page 11: ...voltage indicated on the rating plate or in this Operating Manual Connect the air hose to the Blower by turning the air hose connector clockwise in the blower opening fig 4 6 2 Switching on and Adjust...

Page 12: ...s or borders of the object to be sprayed are properly masked 7 Switching off the Motor Blower After you have finished spraying turn off the Blower by pressing the push button with your thumb Only then...

Page 13: ...lter cap Always replace the intake filter when it is dirty Do not attempt to clean it The intake filter should always be checked before spraying and replaced when dirty as shown in figure 7 This ensur...

Page 14: ...Motor Blower delivers too much or too little air Rotary knob incorrectly set Reset rotary knob such that required air quantity is delivered Motor Blower will not run No mains voltage Check mains conne...

Page 15: ...all employees 11 Spare Parts For safety reasons you should only use ABAC original accessories and ABAC original spare parts Spare parts are available from your ABAC specialist dealer or directly from...