11.
Maintenance of the Projector
11.1
Lamp Replacement
Before lamp replacement the projector must be cooled down completely (wait 30
minutes) and must be disconnected from mains. Only the lamps recommended and
approved by manufacturer can be used. Never touch the new lamp with bare fingers,
due to that skin oil or other particles can burn into the glass bulb of the lamp while
operation of the projector and can damage the new lamp. Please always use a soft
cotton tissue or cotton gloves while touching the lamps (Pic.11.). After replacement
please check the proper position of the new lamp. The original helix should be on the
same height as the reflected helix in order to reach maximum performance (Pic.12).
Pic.11
Pic.12
11.2
Cleaning
For cleaning, particular of the optical surfaces like fresnel lens, mirror and lens
please use soft tissue and clean water only without any chemicals.
12.
Repair Service
In case that you need repair assistance, please contact your local authorized service
provider or contact us under [email protected].
We would be happy to assist you.
13.
Technical Data
top vision 800 top version 1300
Mains
230V/370W 230V/520W
Brightness
2400 ANSI lm
4500 ANSI lm
Lamp
24V/250W 36V/400W
Focal Length
320mm
320mm
10