5.6. Switch setting
5.6.1. Switch and jumper settings during commissioning
Fig. 23
The setting of the HEX switch is indicated by a printed arrow. If the set value is changed, the displayed adjust-
ment setting clearly snaps into place. If position "0" is set when setting the switch, LEDs H1 – H4 briefly light
up. This indicator is provided so that adjustments an be made even under poor lighting conditions.
Turn clockwise to increase the setting incrementally until the individual table value is reached.
S1
Mode
User
CAN
Automatic reopening
(150 N – characteristic curve)
0
Diagnostic unit
= 0
Parameter
1
Not possible
= 1
0 (inactive)
2
Not possible
= 2
0 (inactive)
3
Not possible
= 1
1 (active)
4
Not possible
= 2
1 (active)
5
SIEI-AREG
= 0
0 (inactive)
Default
6
SIEI-AREG USA
= 0
1 (active)
Tab. 31 Settings for HEX switch S1
CAN = 0
… Door is not actuated via CAN.
This is actually only possible!!
CAN = 1
… CAN front side (HS)
Not possible !!
CAN = 2
… CAN rear side (DL)
Not possible !!
In normal operation, only the effect of the parameter setting "Automatic Reopen" (AAU) is overwritten directly
by position 1 – 6 of the HEX switch. This means that the door is also reopened with parameter AAU = 0, e.g.,
in position S1 = S3. The value for "
CAN operation"
, on the other hand, is programmed according to switching
position S1 - position 0– 6 - during automatic commissioning!
This parameter is effective immediately, independent of switching position S1.
S2
Mode
Max. kinet.
energy
Max. speed,
open
Max. speed,
close
Ratio Impulses
/cm
0
Diagnostic unit
1
Slow
7 J
0.3 m/s
0.25 m/s
i = 130
Replace F5 and F9
2
normal
10 J
0.45 m/s
0.3 m/s
i = 130
Replace F5 and F9
3
Fast
20 J
0.65 m/s
0.4 m/s
i = 130
Replace F5 and F9
4
Slow
7 J
0.3 m/s
0.25 m/s
i = 64
Replace F12
5
normal
10 J
0.45 m/s
0.3 m/s
i = 64
Replace F12
6
Fast
20 J
0.6 m/s
0.35 m/s
i = 64
Replace F12
7
Glass door, slow
5.9 J
0.3 m/s
0.25 m/s
i = 130
Replace F5 and F9
8
Glass door, normal
8.4 J
0.45 m/s
0.3 m/s
i = 130
Replace F5 and F9
9
Glass door, fast
16.8 J
0.65 m/s
0.4 m/s
i = 130
Replace F5 and F9
36