13
80991C_MHW_GF_VEDO SL_09-2017_ENG
120°
45°
The angulation of the controller must be between 45° and
120°, as shown in figure 5.
Figure 5 - GF_VEDO SL admitted angulation
Figure 7 - Assembly of seal, metal bracket and terminal connection
Figure 6 - Position and angulation
The angulation to choose also depends on the position of the
controller compared to the operator, as shown in figure 6.
Fastening to the panel
Fit the die-cut rubber seal in the back of the Integrated Con-
troller and Operator (figure 7).
The seal, supplied as standard, is essential to guarantee
IP65-rated protection.
With GF VEDO SL 70CT and GF VEDO SL V70CT, fit the two
metallic brackets supplied into the special housings on the
short sides and fasten them in place with the screws (figure
7).
GF VEDO SL 35CT
GF VEDO SL 70CT
GF VEDO SL V70CT
Figure 8 - Positions available for fastening terminals
Fit the Integrated Controller and Operator in the panel, con-
nect the 4 terminals supplied to the device and tighten the
screw until the device is fastened tightly to the panel.
There are 4 positions in which to connect the terminals, two
per side.