ADV200 SP • Quick start up guide - Specification and installation
6 - Use of the keypad
This chapter describes the keypad and methods of use for display and programming of inverter parameters.
6.1 Description
T+
T-
EN
LOC ILim
n:0
AL
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
7 virtual leds line:
Four alphanumeric lines
with 21-digit each
led is lit
led is off
Membrane keyboard :
• commands
• navigation
LCD display
Membrane keyboard
Inverter control programming menu navigation keys.
Symbol
Reference
Description
Start
Starts the motor
Stop
Stops the motor
ESC
Escape
Returns to the higher level menu or submenu. Exit from a parameter, a list of parameters, from
the list of the last 10 parameters and from the
Goto
parameter function (see CUST).
Can be used to exit from a message that requires use of this.
FWD
REV
Forward/
Reverse
Reverses the direction of rotation of the motor
LOC
REM
Local/Re-
mote
Changes the method of use from local to remote and vice versa.
Is active only if the drive is not enabled.
RST
Reset
Resets alarms only if the causes have been eliminated.
CUST
Custom
The first time it is pressed, displays the list of the last 10 parameters modified.
Pressing this key a second time activates the Goto parameter function for access to a parameter
through its number. To exit these functions, press the
◄
key.
DISP
Display
Displays a list of drive functioning parameters.
E
Enter
Accesses the submenu or parameter selected or selects an operation,
Is used during parameter modification to confirm the new value set.
▲
Up
Moves selection in a menu or a list of parameters up.
During modification of a parameter, increases the value of the digit under the cursor.
▼
Down
Moves the selection in a menu or a list of parameters down.
During modification of a parameter, decreases the value of the digit under the cursor.
◄
Left
Returns to the higher level menu.
During modification of a parameter, moves the cursor to the left.
►
Right
Accesses the submenu or parameter selected.
During modification of a parameter, moves the cursor to the right.
LED’s meaning:
T+
the LED is lit, when the drive operates with a positive torque
T-
the LED is lit, when the drive operates with a negative torque
EN
the LED is lit, when the drive is enabled
LOC
The led is lit when the drive is in local mode and OFF when in remote mode.
Ilim
the LED is lit, when the drive operates at a current limit. During normal functioning, this led is OFF.
n=0
the LED is lit; it signals zero speed
AL
the LED is lit; it signals a trip