5.  ORDER CODES

5. ORDER CODES

5.1.  VDA-I

Electrical connection  

sensor side

M16  6-pin

H

Electrical connection  

controller side

M12  5-pin

A

Output signal

4…20 mA

E

0…±10 VDC

N

Bridge

4/4 bridge

4

2/4 bridge (350 

)

2

Output range of used sensor

2/4 bridge version

 250 

µε

0250

 500 

µε

0500

1000 

µε

1000

4/4 bridge version

0,5 mV/V

0500

1,0 mV/V

1000

2,0 mV/V

2000

3,0 mV/V

3000

Reset type

External high-reset (24V), without power-on reset, zero stored (2·10^6 reset cycles allowed)

HO11

External high-reset (24V), with power-on reset (infinite reset cycles allowed)

HR11

Peak feature

no peak-hold

O

-

-

-

-

-

-

0 0

Order code

VDA-I

Example: 

VDA-I - H - A - N - 2 - 1000 - 00 - HR11 - O 

Variable digital inline amplifier, Electrical connection sensor side = M16 6-pin half bridge, Electrical connection controller side 

= M12 5-pin, Output signal = 0...

±

10 VDC, Bridge = 2/4 (half bridge), Output range of used sensor = 1000

µε

,  

Reset type = external high-reset 24V with power-on reset, no peak-hold

Description

Code

Cable with female connector M12  5-pin

  2 m

CAV011

  5 m

CAV012

10 m

CAV013

15 m

CAV015

Female connector M12  5-pin

TE-E-0103_00

5.2.  Accessories

Summary of Contents for 80537

Page 1: ...INSTRUCTION MANUAL Code 80537 VDA I VARIABLE DIGITAL INLINE AMPLIFIER 80537_MAN_VDA I_10 2017...

Page 2: ......

Page 3: ...neral installation rules 5 2 1 1 1 Protection against infiltration of dust and water 5 2 1 1 2 Minimum space for ventilation 5 2 1 2 Positioning 5 2 2 Electrical connections 5 2 2 1 General rules for...

Page 4: ...fully checked Gefran S p A assumes no liability regarding the presence of any errors or regarding damage to property and or harm to individuals due to any improper use of this manual Gefran S p A als...

Page 5: ...The variable digital inline amplifier VDA I converts the signal from strain sensors and load cells into a voltage or current output signal The VDA I amplifier can be used in dynamic and static applica...

Page 6: ...L DESCRIPTION 1 2 VDA I Main features Amplifier with fast digital output For dynamic and static applications Very high strain gauge bridge offset range Compact solid aluminium housing IP65 1 3 Dimensi...

Page 7: ...temperatur must not exeed 85 C during operation 2 1 2 Positioning Fasten the amplifier to a sufficiently rigid and robust support Use the four through holes on the amplifier and M5 screws Advice The...

Page 8: ...rain gauge 2 6 n a 6 1 2 3 4 5 Excitation Signal Signal Excitation 2 3 1 4 5 6 1 2 3 4 5 Connection pin Function 1 Excitation 2 Excitation 3 Excitation 4 Signal 5 Signal 6 Excitation Sensor 2 4 bridge...

Page 9: ...output signal To run a Reset supply voltage from 12 to 36 V for at least 25 ms there are no limits to longer durations to the Reset input of the function in question It s possible to tare an input si...

Page 10: ...E stretching Allowed load 5 k 0 500 Temperature effects zero 0 01 FS C Temperature effects span 0 01 FS C 1 incl Non linearity Hysteresis Repeatability Zero offset and Span offset 2 Uses 50V 2J Voltag...

Page 11: ...stored 2 10 6 reset cycles allowed HO11 External high reset 24V with power on reset infinite reset cycles allowed HR11 Peak feature no peak hold O 0 0 Order code VDA I Example VDA I H A N 2 1000 00 H...

Page 12: ...80537_MAN_VDA I_10 2017_ENG 10...

Page 13: ......

Page 14: ...GEFRAN Spa Via Sebina 74 25050 Provaglio d Iseo Bs Italien Tel 39 0309888 1 Fax 39 0309839063 info gefran com http www gefran com...

Reviews: