RS-232 / TELNET COMMANDS
#set_input_name Command
The #set_input_name command names the specified input. This feature makes is easier to
keep track of each input (source) device during the routing process. The input name may
contain a combination of letters and numbers.
Special characters and spaces are not permitted. If a space is required as part of the input
name, use the underscore character (“_”).
Syntax:
#set_input_name param1 param2
Parameters:
param1
Input
[1 - 32]
param2
String (15 characters max.)
Example:
#set_input_name 1 DVD_player
DVD_player is assigned to input 1