RS-232 / TELNET / UDP COMMANDS
#lock_edid Command
The #lock_edid command secures the Local EDID and disables the automatic loading of
the downstream EDID after the matrix is powered on. This feature can also be controlled
using the Web Interface (see page 52).
Syntax:
#lock_edid param1
Parameters:
param1
Input
[0
...
1]
Value
Meaning
0
Disable
1
Enable
#prbaedid Command
The #prbaedid command reads the EDID file from the specified bank and sends it to the
serial port.
Syntax:
#prbaedid param1
Parameters:
param1
EDID bank
[1 ... 3]
#prdsedid Command
The #prdsedid command reads the downstream EDID and sends it to the serial port.
Syntax:
#prdsedid param1
Parameters:
param1
A downstream monitor
[1 ... 16]