RS-232 / TELNET / UDP COMMANDS
#ediddstoba Command
The #ededdstoba command reads the downstream EDID and stores it to a
specified EDID bank.
Syntax:
#ediddstoba param1 param2
Parameters:
param1
A downstream monitor
[1 ... 16]
param2
EDID bank
[1 ... 3]
#ediddstolo Command
The #ediddstolo
command reads the downstream EDID and stores it to a Local EDID input.
A maximum of 8 inputs can be specified at a time.
Syntax:
#ediddstolo param1 param2 [param3...param9]
Parameters:
param1
A downstream monitor
[1 ... 16]
param2
Input
[1
...
16]
Notes
:
If
param2 = 0
, then the downstream EDID is stored to all 16 DVI inputs. If more than eight
inputs need to be specified in order to receive the downstream EDID,
the #ediddstolo command must be executed twice.
Example
:
The following is not permitted:
#ediddstolo 2 1 2 3 4 5 6 7 8 9 10 11
Instead, run the function twice:
#ediddstolo 2 1 2 3 4 5 6 7 8
#ediddstolo 2 10 11