background image

page | 2

Getting Started

Pre-Configured Options

The following list outlines the available pre-configured options.  Because this User Manual 

covers information on all available configurations, it is important to identify the type of 8x8 

Modular Matrix that was purchased.
 

• 

8 DVI Input / 8 DVI Output (GEF-MOD-848-DVI)

 

 

One input card using eight DVI inputs, providing a total of 8 DVI inputs. 

 

One output card using eight DVI outputs, providing a total of 8 DVI outputs. 

 

 

Packing List: 

 

(1) 8x8 Modular Matrix Frame

 

(1) Modular Matrix 8 DVI Input Card

 

(1) Modular Matrix 8 DVI Output Card

 

(1) DB-9 cable

 

(2) AC power cords

 

(1) Quick-Start Guide

• 

8 DVI Input / 8 CAT-5 ELR Output (GEF-MOD-848-DVIELR)

 

 

One input card using eight DVI inputs, providing a total of 8 DVI inputs. 

 

One output card using eight ELR-POL outputs.  Each of these ELR-POL outputs are 

connected to a Receiver unit, using a CAT-5e cable, allowing you to extend the DVI 

signal up to 330 feet (100 meters).  8 ELR-POL Receiver units are included with this 

package option. 

 

 

Packing List: 

 

(1) 8x8 Modular Matrix Frame

 

(1) Modular Matrix 8 DVI Input Card

 

(1) Modular Matrix 8 DVI Sender over CAT-5 Card

 

(8) DVI ELR Receivers with POL

 

(1) DB-9 Cable

 

(2) AC Power Cords

 

(1) Quick-Start Guide

 

Summary of Contents for GEF-MOD-848-1FO

Page 1: ...der 3GSDI Release A4 User Manual GEF MOD 848 DVI GEF MOD 848 DVIELR GEF MOD 848 ELR GEF MOD 848 DVI1FO GEF MOD 848 1FO GEF MOD 848 DPDVI GEF MOD 848 DPELR GEF MOD 848 DP1FO 8 8 x DISPLAYS SOURCES Modu...

Page 2: ...re they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 To reduce the risk of electric shock and or damage to this product never handle or touch this unit...

Page 3: ...disclaimed 1 Proof of sale may be required in order to claim warranty 2 Customers outside the US are responsible for shipping charges to and from Gefen 3 Copper cables are limited to a 30 day warranty...

Page 4: ...M to 5 00 PM Monday Friday Pacific Time For 24 7 support see the back of the product for the support number 8x8 Modular Matrix is a trademark of Gefen LLC Important Notice Gefen LLC reserves the right...

Page 5: ...ion be used by all of the source devices Routing features can be accessed using RS 232 or IP control See RS 232 and IP Configuration for more information The 8x8 Modular Matrix provides several differ...

Page 6: ...sor and rear panel IR port Front panel LCD display Front panel push buttons for local switching Routing states can be stored and recalled at the touch of a button Dual redundant hot swappable power su...

Page 7: ......

Page 8: ...he 8x8 Modular Matrix Front Panel Controls 24 Front Panel Buttons 24 Front Panel LCD Screen 25 Displaying Matrix Settings 26 Routing Basics 27 Routing Inputs to Outputs 27 Getting the Current Routing...

Page 9: ...11 Configuration Change IP Settings 112 Configuration TCP Telnet Terminal Login Settings 113 Configuration UDP Connection Settings 114 Configuration Web Login Settings 115 Configuration System Configu...

Page 10: ......

Page 11: ...6 Front Panel 6 Back Panel 7 IR Remote Control Unit 8 Front 8 Back 9 Installing the Battery 10 Setting the IR Channel 10 Installation 11 Sample Wiring Diagram 11 GEF MOD 848 DVI 12 GEF MOD 848 DVIELR...

Page 12: ...Modular Matrix 8 DVI Input Card 1 Modular Matrix 8 DVI Output Card 1 DB 9 cable 2 AC power cords 1 Quick Start Guide 8 DVI Input 8 CAT 5 ELR Output GEF MOD 848 DVIELR One input card using eight DVI i...

Page 13: ...able allowing you to extend the DVI signal up to 330 feet 100 meters 8 ELR POL Receiver units are included with this package option Packing List 1 8x8 Modular Matrix Frame 1 Modular Matrix 8 ELR Input...

Page 14: ...inputs Each of these fiber optic inputs are connected to a Sender unit using single strand 50 OM3e OM4 multimode fiber optic cable allowing you to extend the matrix up to 6600 feet 2 kilometers away...

Page 15: ...DVI Modular Receivers over 1FO 8 Power supplies for DVI Modular Receivers over 1FO 1 Quick Start Guide 8 DisplayPort Input 8 Fiber Output GEF MOD 848 DP1FO One input card using eight DisplayPort inpu...

Page 16: ...nformation on routing sources 3 In Used for routing an Input to an Output Each of these buttons represents an Input See Routing Basics for more information on routing sources 4 Power This LED indicato...

Page 17: ...EXT RMT EXTIRN 4 Power This LED indicator will glow bright blue when the matrix board is powered 5 Power supply 100 240V AC internal hot swappable power supply 6 IEC connector Connect the included AC...

Page 18: ...This LED glows bright orange when a key is pressed on the remote 2 Input buttons 1 8 Used to select the desired input output when routing Getting Started IR Remote Control Unit NOTE The IR remote cont...

Page 19: ...the IR Channel for more information 2 Primary battery slot shown without battery Holds the battery for operating the remote Use only 3V CR2032 type batteries Make sure that the positive side of the b...

Page 20: ...control to communicate with the 8x8 Modular Matrix the IR remote control must be set to the same channel as the matrix See the set_ir command for instructions on setting the IR channel of the matrix W...

Page 21: ...12 GEF MOD 848 ELR page 14 GEF MOD 848 DVI1FO page 16 GEF MOD 848 1FO page 18 GEF MOD 848 DVIDVI page 20 GEF MOD 848 DPELR page 20 GEF MOD 848 DP1FO page 20 Sample Wiring Diagram WARNING This product...

Page 22: ...fail It is recommended to connect each power cord to electrical outlets on two separate circuits GEF MOD 848 DVIELR 1 Connect up to 8 DVI sources to the DVI inputs on the rear panel of the 8x8 Modula...

Page 23: ...unit is delivered from the power supply in the matrix over the CAT 5e cable using Gefen Power Over Line POL technology The Link indicator will glow bright green to indicate a solid connection between...

Page 24: ...using DVI cables 2 Connect a CAT 5e cable or better up to 330 feet 100 meters from each Sender unit to each ELR POL jack on the Receiver card as shown below Getting Started Installation DVI cable DVI...

Page 25: ...ical outlets on two separate circuits Power to both the Sender and Receiver unit is delivered from the matrix over the CAT 5e cable using Gefen Power Over Line POL technology The Link indicator will g...

Page 26: ...it as shown below 50 OM3e OM4 OM3 and 62 5 OM1 multimode fiber optic cable can be used However the maximum extension distance will be dependent upon the type of fiber optic cable used Refer to the tab...

Page 27: ...power cords will provide power redundancy should one of the power supplies fail It is recommended to connect each AC power cord to separate circuits The Link indicator on the Receiver unit will glow b...

Page 28: ...e strand of SC terminated multimode fiber optic cable from each SC type connector on the Receiver card to each Sender unit as shown below Remove the protective rubber cap from the SC connector before...

Page 29: ...indicate a solid connection between the matrix and the Receiver unit The Power indicator will glow bright blue to indicate that the Sender and Receiver units are being powered Connect both AC power c...

Page 30: ...atrix Once the matrix is powered the Link indicators will glow bright green to indicate a solid link between the Matrix card and the Receiver unit The POL indicators will glow bright amber to indicate...

Page 31: ......

Page 32: ......

Page 33: ...ent Routing Status 29 One to One Routing 30 Saving the Current Routing State 31 Recalling a Saved Routing State 33 Masking 35 Masking Outputs 35 Getting the Current Masking Status 37 Unmasking Outputs...

Page 34: ...bottom row of 8 buttons represent the inputs For example button 1 on the top row represents Output 1 button 2 represents Output 2 and so on The input buttons on the bottom row are arranged in a simila...

Page 35: ...of the matrix When the matrix has been powered ON power cycled or rebooted the following three screens will appear in order LCD Screen Description EDID LOADING PLEASE WAIT Matrix is loading EDID data...

Page 36: ...on is not pressed within a certain amount of time LCD Screen Description MATRIX FIRMWARE 0 04 07 Displays the current version of the firmware IP ADDRESS 192 168 2 235 Displays the current IP address o...

Page 37: ...routing masking or preset operation The Set button will glow bright blue indicating that it has been pressed 2 The LCD on the front panel will indicate that routing mode is active 3 Press the desired...

Page 38: ...lls the matrix that we have completed the routing operation Once the Set button has been pressed the LCD will indicate that the routing process has been completed 6 After a few moments the selected bu...

Page 39: ...ss the button 1 on the top row of buttons When we pressed 1 on the top row button 2 on the bottom row was also selected This tells us that Input 2 has been routed to Output 1 2 Now press button 3 on t...

Page 40: ...see that Input 4 is routed to Output 4 This is called one to one routing We could have achieved the same result by pressing Output 4 One to One Routing When an input output pair share the same number...

Page 41: ...ke sure we are saving the correct routing state press the button for Input 2 on the front panel The following routing state should be displayed This is the routing state we created under the section R...

Page 42: ...by pressing button 1 5 Press the Set button to store the routing state in the selected location The Set button will flash momentarily 6 After a few moments the selected buttons will turn off and the...

Page 43: ...ks try changing the routing state of Input 6 to Output 2 Then use the steps below to recall the original routing state See Routing Inputs to Outputs if necessary 1 Press the PreSet button once The LCD...

Page 44: ...ion The Set button will flash momentarily 4 After a few moments the PreSet button and button 1 will turn off and the LCD will return to the Home screen Routing Basics Operating the 8x8 Modular Matrix...

Page 45: ...e outputs can be masked To illustrate masking we ll use our original routing example from page 27 1 Press the Mask button The Mask button will glow bright blue and the LCD will indicate that the matri...

Page 46: ...pressed the LCD display will indicate that the masking process was successful 5 After a few moments the selected buttons will turn off and the LCD will return to the Home screen Masking Operating the...

Page 47: ...will glow bright blue and the LCD will indicate that the matrix is in mask mode If any outputs are currently masked they will be indicated on the front panel For example since we recently masked Outpu...

Page 48: ...s example and unmask Output 3 and Output 5 1 Press the Mask button The Mask button will glow bright blue and the LCD will indicate that the matrix is in mask mode Once the Mask button is pressed any o...

Page 49: ...is pressed the LCD display will indicate that the unmasking process was successful 5 After a few moments the matrix will return to the Home screen Masking Operating the 8x8 Modular Matrix MASK MODE MA...

Page 50: ...t panel 1 Press the Lock button under the Mode group The Lock button will glow bright blue indicating that the matrix is now locked 2 The LCD display will also indicate that the matrix has been locked...

Page 51: ...EDID to an Input 1 Press the EDID button once The EDID button will glow bright blue and the LCD will indicate that the matrix is ready to copy the downstream EDID DSTOLO is an abbreviation for DownSt...

Page 52: ...pying the downstream EDID from the display or other sink to the EDID from the selected output to the specified input The LCD will indicate that the matrix is copying the EDID 6 After the EDID has been...

Page 53: ...page 43 7 After a few moments the selected buttons will turn off and the LCD will return to the Home screen EDID Management Operating the 8x8 Modular Matrix GEFEN MODULAR MATRIX GEFEN MODULAR MATRIX...

Page 54: ...t can be used Let s look at an example 1 Press the EDID button twice The EDID button will glow bright blue and the LCD will indicate that the matrix is ready to copy the default EDID to the specified...

Page 55: ...the matrix is copying the EDID 5 After the EDID has been successfully copied to the selected input the LCD will display the following message 6 After a few moments the selected buttons will turn off a...

Page 56: ...routing state Input 1 Output 1 Input 2 Output 2 and so on 1 From the home screen press and hold the EDID and Cancel buttons for 3 seconds 2 Release the EDID and Cancel buttons when the following scre...

Page 57: ...tput 3 1 Point the IR remote at the IR sensor on the front panel of the matrix 2 Select the input by pressing button 5 on the IR remote control unit The LED on the IR remote control unit will flash br...

Page 58: ...output will turn off Using the IR Extender There may be situations where the IR sensor is blocked by a cabinet or other mounting device In this case an IR extender Gefen part no EXT RMT EXTIR can be c...

Page 59: ......

Page 60: ......

Page 61: ...b Interface 94 Using the built in Web Server 94 Routing Routing 95 Routing I O Names 100 Routing 5V 101 Routing Output Masks 103 Status In Out 105 Status System 106 Manage EDID Assign 107 Manage EDID...

Page 62: ...top bits 1 Hardware flow control None IMPORTANT When sending RS 232 commands a carriage return must be included at the end of the command A space must be included between the command and the parameter...

Page 63: ...erminal and use the RS 232 settings listed on the previous page 3 Set the IP address for the matrix using the sipadd command 4 Set the subnet mask using the snetmask command 5 Set the gateway router I...

Page 64: ...nstream EDID from bank and sends to serial port prdsedid Read downstream EDID and sends to serial port predidst Spools the EDID details to the serial port prloedid Read Input Local EDID and sends to s...

Page 65: ...ult Internal EDID to the specified input s At least one input must be specified If param2 0 then the EDID in the specified bank is copied to all 8 inputs Syntax ediddetolo param1 param9 Parameters par...

Page 66: ...oading Downstream EDID 5 to EDID bank 17 please wait Finished Loading ediddstolo The ediddstolo command reads the downstream EDID and stores it to a Local EDID If param2 0 then the EDID in the specifi...

Page 67: ...nabled or disabled Syntax lock_edid param1 Parameters param1 Value 0 1 Value Description 0 Disable Lock EDID 1 Enable Lock EDID loedidtoba The loedidtoba command loads an EDID file and stores it in th...

Page 68: ...nd stores it in the specified input If param1 0 then the downstream EDID is stored in all 8 inputs Syntax loedidtolo param1 Parameters param1 Input 1 8 Example loedidtolo 8 Download EDID bin file___1...

Page 69: ...3 0x80 0x41 0x29 0x78 0xEA 0x8F 0x95 0xAD 0x4F 0x32 0xB2 0x25 0x0F 0x50 0x54 0xA5 0x4B 0x00 0x81 0x80 0xA9 0x40 0xD1 0x00 0xD1 0x40 0x71 0x4F 0x81 0x00 0xB3 0x00 0x01 0x01 0xB0 0x68 0x00 0xA0 0xA0 0x4...

Page 70: ...x01 0x03 0x80 0x41 0x29 0x78 0xEA 0x8F 0x95 0xAD 0x4F 0x32 0xB2 0x25 0x0F 0x50 0x54 0xA5 0x4B 0x00 0x81 0x80 0xA9 0x40 0xD1 0x00 0xD1 0x40 0x71 0x4F 0x81 0x00 0xB3 0x00 0x01 0x01 0xB0 0x68 0x00 0xA0 0...

Page 71: ...ntax predidst param1 Parameters None Example predidst EDID table Input ID Monitor name Source name 1 GFN GEFEN_XPT_SL Default 2 GFN GEFEN_XPT_SL Default 3 GFN GEFEN_XPT_SL Default 4 GFN GEFEN_XPT_SL D...

Page 72: ...0x00 0xBA 0x88 0x21 0x00 0x00 0x9E 0x00 0x00 0x00 0xFC 0x00 0x50 0x61 0x6E 0x61 0x73 0x6F 0x6E 0x69 0x63 0x54 0x56 0x30 0x0A 0x00 0x00 0x00 0xFD 0x00 0x17 0x3D 0x0F 0x44 0x0F 0x00 0x0A 0x20 0x20 0x20...

Page 73: ...cter Use the show_bank_name command to display the specified bank name Syntax set_bank_name param1 param2 Parameters param1 EDID bank 1 20 param2 Name Example set_bank_name 3 Dell_30 Dell_30 is assign...

Page 74: ...Sets the remote UDP IP address set_udp_rport Sets the remote UDP port sgateway Sets the IP address of the router gateway show_tcp_term_pass Displays the current TCP terminal password sipadd Sets the...

Page 75: ...e rebooted after executing this command Syntax resetip Parameters None set_http_port The set_http_port command specifies the Web server listening port The matrix must be rebooted after executing this...

Page 76: ...param2 param3 Parameters param1 Old password param2 New password param3 New password confirmation Example set_tcp_term_pass Admin reindeer reindeer TCP Terminal password updated to reindeer set_tcp_t...

Page 77: ...ers param1 Port 1 65535 Example set_udp_port 56 New UDP server port set to 56 set_udp_rip The set_udp_rip command sets the remote UDP listening IP address The IP address must be specified using dot de...

Page 78: ...set_udp_rport param1 Parameters param1 Port 1 65535 Example set_udp_rport 1024 New UDP Remote port set to 1024 sgateway The sgateway command sets the new IP gateway The gateway must be typed using dot...

Page 79: ...he set_tcp_term_pass command to set the password Syntax show_tcp_term_pass Parameters None Example show_tcp_term_pass TCP Terminal password reindeer show_user_name The show_user_name command displays...

Page 80: ...the matrix is 192 168 1 72 Syntax sipadd param1 Parameters param1 IP address Example sipadd 192 168 1 127 New IP set to 192 168 1 127 snetmask The snetmask command sets the subnet mask The net mask m...

Page 81: ...Parameters param1 Value 0 1 Value Description 0 Disable password prompt 1 Enable password prompt Example use_tcp_term_pass 1 TCP Terminal password at login is set to ON use_udp_access The use_udp_acc...

Page 82: ...e specified name show_input_name Displays the specified input name show_output_name Displays the specified output name show_preset_name Displays the specified preset name unmaskout Unmasks the specifi...

Page 83: ...maskout command masks the specified outputs If param2 0 then all outputs will be masked At least one output must be specified Syntax maskout param1 param9 Parameters param1 Output 1 8 Example maskout...

Page 84: ...reset Parameters None Example prpreset Preset table Set Outputs 1 8 1 A 0 A 0 A 0 A 0 A 0 A 0 A 0 A 0 2 A 0 A 0 A 0 A 0 A 0 A 0 A 0 A 0 3 A 0 A 0 A 0 A 0 A 0 A 0 A 0 A 0 4 A 0 A 0 A 0 A 0 A 0 A 0 A 0...

Page 85: ...8 Example savepreset 2 Current routing state is saved to preset set_input_name The set_input_name command names the specified input The name of the input cannot exceed 20 characters in length Spaces...

Page 86: ...param1 param2 Parameters param1 Output 1 8 param2 Name Example set_output_name 7 Dell_24 Dell_24 is assigned to output 7 set_preset_name The set_preset_name command names the specified preset The nam...

Page 87: ...pecified input Syntax show_input_name param1 Parameters param1 Input 1 8 Example show_input_name 4 Input 4 signal_generator show_output_name The show_output_name command displays the name of the speci...

Page 88: ...Parameters param1 Preset 1 8 Example show_preset_name 2 Preset 2 Studio51 unmaskout The unmaskout command unmasks the specified output s Multiple outputs can be specified If param1 0 then all outputs...

Page 89: ...displayed based on the current IR channel of the matrix Do not precede this command with the symbol Syntax m Parameters None Example m Show the matrix status in tabular form Routing status table Outpu...

Page 90: ...an be specified at a time Do not precede this command with the symbol If param2 0 then the specified input will be routed to all outputs Also see the s command Syntax r param1 param2 param9 Parameters...

Page 91: ...o not precede this command with the symbol If param1 0 then the matrix will be placed in a 1 to 1 routing state In other words Input 1 is routed to Output 1 Input 2 is routed to Output 2 and so on Syn...

Page 92: ...ommands hpdto Cycles with HPD line on the specified output lock_fo Enables disables the power lock state reboot Reboots the matrix set_ir Sets the IR channel of the matrix show_temp Displays the tempe...

Page 93: ...ets the matrix to factory default settings Syntax factory_reset Parameters None Example factory_reset IP configuration reset to factory default Reset to factory default Please wait Routing 1 1 2 2 Unm...

Page 94: ...ed Syntax fadefault Parameters None Example fadefault Reset to factory default Please wait Routing 1 1 2 2 Unmasked all Outputs Loading default EDID to all locals Inputs please wait Finished Loading f...

Page 95: ...onal Notes When asking for help on a specific command the character must be included as part of the command Example help maskout Cmd maskout Mask outputs Syntax maskout param1 param8 Param1 0 All outp...

Page 96: ...Syntax hpdto param1 Parameters param1 Input 1 8 Example hpdto 6 HPD cycle on input 6 lock_fo The lock_fo command enables disables the power lock state Enabling this feature will store the 5V status fo...

Page 97: ...ant 10 Example reboot 10 The system will reboot itself please wait GEFEN Modular MultiMatrix UI FW version 0 4 09 Establish connection with Input Board 1 Board Type DVI input 8 channels Board SN 95485...

Page 98: ...with the matrix both the matrix and the IR remote must share the same IR channel After executing this command the DIP switch settings for the included IR remote control unit are returned See Setting...

Page 99: ...rd within the matrix Syntax show_temp Parameters None Example show_temp Temperature result C deg for UI board 28 Temperature results C deg for BP board sensor1 Mindspeed 31 sensor2 power 27 Temperatur...

Page 100: ...he current hardware and firmware version Syntax show_ver_data Parameters None Example show_ver_data UI Firmware Release version 0 4 09 Release date Mar 20 2013 Release time 12 39 54 BP Firmware Releas...

Page 101: ...ers None Example show_voltage ADC UI measurment result VCC CORE 1 8 Value 1854 mVolt PSU1 DS460 PSU1 PSOK Value 3067 mVolt PSU1 Imon Value 125 mV 1 A Power results mV for BP board 5V 3 3V 1 2V 5092 33...

Page 102: ...RS 232 IP Commands strto_in The strto_in command is for future hardware use Syntax Not available Parameters Not available strto_out The strto_out command is for future hardware use Syntax Not availabl...

Page 103: ...f The f command enables disables the 5V on the specified input Do not precede this command with the symbol Syntax f param1 param2 Parameters param1 Input 1 8 param2 Value 0 1 Value Description 0 Disab...

Page 104: ...the matrix the login screen will be displayed Username Select the username from the drop down list Options Operator Administrator Administrator login provides unrestricted access to all features and...

Page 105: ...rface NOTE In order to access all features the user must be logged in as Administrator If the user is logged in as Operator only the Routing tab will be visible Input Click the radio button next to th...

Page 106: ...can be made using the Web GUI When the matrix is locked the button text will read Unlock Matrix and a red bar will appear across the top portion of the screen with the text Matrix is LOCKED Click the...

Page 107: ...put Click to place a check mark in the box and select the desired output Multiple outputs can be selected at a time Type Indicates the type of output card that is present in the expansion bay Check Al...

Page 108: ...set Saves the current routing state to memory Click the drop down list to select the desired routing preset Click the Save button to save the preset to memory Recall Routing Preset Loads the selected...

Page 109: ...ing Preset Names Advanced Operation Web Interface Name Type the desired name of the Preset in this field Save Changes Click this button to save the Preset Name Cancel Click this button to cancel the n...

Page 110: ...Names Advanced Operation Web Interface Save Changes Click this button to save the Input Output name Cancel Click this button to cancel the name change s Name Type the desired name of each Output or I...

Page 111: ...er of each Input If the input has 5V enabled it will be highlighted in green as shown Name The current name of each input 5V Click to select the desired Input s Selecting an input does not automatical...

Page 112: ...to enable 5V on the selected input s See the previous page for information on selecting inputs Cancel Restores the previous 5V state for each input if a change was made 5V ON legend If 5V has been en...

Page 113: ...mber of each output If the output has been masked it will be highlighted in blue as shown Name The current name of each output Mask Click to select the desired Output s to be masked Selecting an outpu...

Page 114: ...this button to enable masking on the selected output s See the previous page for information on selecting inputs Cancel Restores the previous masking state for each output if a change was made Masked...

Page 115: ...tion on the hardware and firmware of the 8x8 Modular Matrix The OUTPUTS column lists each Output Card that is installed The INPUTS column lists each Input Card that is installed The information presen...

Page 116: ...ystem tab provides additional detailed information on the 8x8 Modular Matrix hardware The information presented on this screen is used by Gefen Technical Support for troubleshooting purposes only Adva...

Page 117: ...EDID button is clicked enabled the EDID locked on power cycle message will be displayed in red The local EDID information will now be locked once the matrix is rebooted Click the Unlock EDID button to...

Page 118: ...y using the name command Checkbox Click to select the Input s to where the EDID source will be copied Selecting an input does not automatically copy the EDID source Click the Copy button to copy the E...

Page 119: ...nput In the illustration above the EDID source is Output 1 EDID Name Displays the name of the current EDID being used on the input Advanced Operation Web Interface Copy Copies the EDID source to the s...

Page 120: ...Name Type the desired name of the EDID bank in this field Click the Save Changes button to save the bank name Click the Cancel button to restore the previous name Save Changes Saves the current name...

Page 121: ...DID file will be saved in binary format bin Options Bank_1 Bank_20 Output_1 Output_8 Input_1 Input_8 Upload Click this button to upload the EDID to the specified bank Download Click this button to dow...

Page 122: ...e Settings Saves the current settings for the Change IP Settings After clicking this button the Web interface will display a dialog indicating that the matrix must be rebooted for changes to take effe...

Page 123: ...orce Password on Connect Click this check box to have the matrix prompt for a password each time a Telnet session is started Show Login Message on Connect Click this check box to have the matrix displ...

Page 124: ...tion Web Interface Remote UDP IP Address Type the remote UDP IP address in this text box Remote UDP Port Enter the remote UDP port in this text box Enable UDP Access Check this box to enable UDP acces...

Page 125: ...ck this drop down list to select the username to be changed Old Password Type the current old password in this field New Password Type the new password in this field Confirm Password Re type the new p...

Page 126: ...current configuration to a file NOTE As of this writing the firmware upgrade procedure is not functional from within the Web interface This feature will be available in a future release of the produc...

Page 127: ...ck this button to set the matrix to factory default settings The IP settings are preserved Reboot Click this button to reboot the matrix Browse Click this button to select the saved configuration file...

Page 128: ......

Page 129: ...Matrix 8 DVI Input Card 128 Modular Matrix 8 DisplayPort Input Card 128 Modular Matrix 8 ELR Input Card 128 DVI ELR Sender with POL 129 Modular Matrix 8 FO Input Card 129 DVI Sender over 1 FO 130 Mod...

Page 130: ...d Each card cover plate has two fastening screws WARNING Modules are sensitive to Electrostatic Discharge ESD which can damage the module Avoid touching the module contacts or the components on the mo...

Page 131: ...cover plate is being removed then loosen the fastening screws on both sides of the cover plate and gently remove the cover plate 5 Locate the grooved metal track on either side of the expansion bay 6...

Page 132: ...e card with both thumbs until it snaps in place 32x32 Modular Matrix shown 8 Secure the card by hand tightening the fastening screws Do not overtighten the screws To prevent damage to the screws do no...

Page 133: ...and IP Configuration for configuration information 3 Type the command fw_update 4 The following will be displayed on the terminal screen Download new FW_____1 cancel______________0 5 Press the 1 on t...

Page 134: ...n 0 3 38 Establish connection with Input Board 1 Board Type DP input 8 channels Board SN 959800 FW ver 0 3 8 Establish connection with Input Board 2 Board Type DP input 8 channels Board SN 959793 FW v...

Page 135: ...ds Please wait Finished loading new FW version to all IN OUT boards The system will reboot itself please wait GEFEN Modular MultiMatrix UI FW version 0 3 38 Establish connection with Input Board 1 Boa...

Page 136: ...t Loader v 3 7 Checking program CS in SPI flash Please wait Erasing internal FLASH please wait Writing internal FLASH please wait Download Completed Successfully GEFEN Modular MultiMatrix UI FW versio...

Page 137: ...d used 8 x DVI I 29 pin female digital only 8 x DisplayPort female 8 x ELR POL RJ 45 8 x Fiber SC type Outputs 8 x max organized into banks of 8 depending upon the type of input card used DVI I 29 pin...

Page 138: ...Card GEF MOD 8DP I Output Data Rate 2 7 Gbps TMDS Input Video Signal 1 2V p p Input Connectors 8 x DisplayPort 20 pin female Dimensions W x H x D 15 75 x 1 x 10 5 400mm x 26mm x 267mm Unit weight 2 lb...

Page 139: ...x LED green POL Indicators 8 x LED red Dimensions W x H x D 15 75 x 1 x 10 5 400mm x 26mm x 267mm Unit weight 2 lbs 0 9 kg Modular Matrix 8 FO Input Card GEF MOD 8FO R Maximum Pixel Clock 165 MHz Fibe...

Page 140: ...0 64 kg Modular Matrix 8 DVI Output Card GEF MOD 8DVI O Maximum Pixel Clock 165 MHz Output Connectors 8 x DVI 29 pin female digital only Power Indicator 1 x LED blue Dimensions W x H x D 15 75 x 1 x...

Page 141: ...VI 8FO S Maximum Pixel Clock 165 MHz Fiber Optic Connectors 1 x SC type per input 8 total Dimensions W x H x D 15 75 x 1 x 10 5 400mm x 26mm x 267mm Unit weight 2 lbs 0 9 kg DVI Receiver over 1 FO GEF...

Page 142: ...uct uses UL or CE listed power supplies 20600 Nordhoff St Chatsworth CA 91311 1 800 545 6900 818 772 9100 fax 818 772 9120 www gefenpro com support gefenpro com Pb Stretch it Switch it Split it Gefen...