GH10PA USER MANUAL
PAGE
5
PPUH “GECO” Sp. z o.o. [Ltd.] Issue II
SINCE DECEMBER 2011
3.
TECHNICAL DATA
Working voltage
230V AC +10% -15%
Resistance characteristics
for NTC sensors
Working temperature
from +5
°
C to +40
°
C
Humidity
from 20% to 80% RH
Temperature
°C
Resistance
Fan and Feeder protection
3,15A
0
7174,89
Sensor type
NTC 2,2k
10
4374,83
Temp. sensor operating range
0
°
C÷100
°
C
20
2747,10
30
1774,91
Output
Maximum
continuous load
40
1172,09
50
795,08
CH pump
1A
200W
60
547,95
Container feeder
2A
400W
70
384,62
Burner feeder
2A
400W
80
275,86
Fan
1A
200W
90
202,37
Heater
3A
600W
100
149,16
4.
ELECTRICAL SYSTEM AND CONNECTION RULES
Boiler room should be equipped with 230V/50Hz electrical system according to applicable regulations.
Electrical system (regardless of its type) should end with a plug-in socket equipped with protective contact.
Using a socket without connected protective contact may result in electric shock !!!
The controller needs to be connected to a separate power supply line protected with a properly selected
quick fuse and differential current switch (anti-electric shock).
It is forbidden to connect any other equipment
to this line !!!
THE CONTROLLER IS POWERED FROM 230V/50HZ MAINS
ANY REPAIRS MAY BE CARRIED OUT ONLY WITH POWER SUPPLY
CUT OFF AT THE FUSE