GH10PA USER MANUAL
PAGE
14
PPUH “GECO” Sp. z o.o. [Ltd.] Issue II
SINCE DECEMBER 2011
7.
USER SETTINGS
7.1.
Boiler preset temperature (U0)
You can change the boiler temperature setting applying the following procedure:
7.2.
Feeder working time (U1)
This setting informs the user about the time for which the fuel feeder will be activated in the AUTO mode.
Settings are within range of 2s to 250s.
You can change the setting using the following procedure:
STEP 1
STEP 2
STEP 3
STEP 4
→
→
or
→
The green LED lights
up on the key.
The display shows
U0 parameter
current setting.
Go to U1
Set the new desired
value.
Save the new
temperature
setting.
Move to the U2
setting.
7.3.
Feeder stop time (U2)
This is the period of time between two consecutive fuel feeds in the AUTO mode. Settings are within the
range from 5s to 250s.
You can modify this setting applying a procedure similar to the one described in section 7.2.
STEP 1
STEP 2
STEP 3
→
or
→
The green LED lights up
on the key.
The display shows
current temperature
setting.
Set the new desired
temperature within the
range permitted by the
boiler manufacturer.
Save the new
temperature setting.
Move to the U1
setting.
If during setting the new temperature
none of the following keys
,
,
is pressed for 15 s, the new temperature will not be saved
and the Controller will exit the programming mode.