background image

GECKO® SAFETY INSTRUCTIONS & SYMBOLS GUIDE

GECKO® SAFETY INSTRUCTIONS & SYMBOLS GUIDE

For your own safety and to avoid invalidation of the warranty, all text marked with these symbols should be  
read carefully. 

SYMBOLS:

SYMBOLS: 

 

 

 

         

     

SAFETY INSTRUCTIONS:

SAFETY INSTRUCTIONS:

To reduce the risk of electrical shock, do not remove covers. No user serviceable parts inside. Please 
refer servicing to qualified personnel.

To reduce the risk of electrical shock or fire, do not expose the equipment to rain or moisture. 

Do not impose unnecessary stress on your equipment (i.e. placing heavy objects on it, overscrewing its 
mounting etc). 

Read and keep the instruction manuals in a safe place for future references.

Do not attempt to clean the equipment with chemical solvents as this may damage the finish. Clean only 
with dry cloth.

Do not block any ventilation openings. 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that 
produce heat.

Do not defeat the purpose of the polarized or grounding type plug. A polarized plug has two blades with 
one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide  
blade or the grounding prong is provided for your safety. If the provided plug does not fit into your outlet, 
consult an electrician for the replacement of the obsolete outlet.

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles,  
and the point where they exit from the apparatus.

Unplug the apparatus during lightning storms or when it is not in use for a long period of time.

NOTES

NOTES

 

Contain important information and useful tips on the operation of your equipment. 

WARNING

WARNING 

The  lightning  flash with arrowhead symbol within an equilateral triangle, is intended to 
alert  the  user  to  the  presence  of  uninsulated  dangerous  voltage  within  the  product’s 
enclosure that may be of sufficient magnitude to constitute a risk of electric shock. 

CAUTIONS

CAUTIONS

The  exclamation point 

within 

an equilateral triangle is intended to alert the user to the 

presence  of

 

important 

opera

ting  and  maintenance  (servicing)  instructions  in  the

e

 

literature accompanyin

g

 the

 app

liance. Please read the manual carefully.

H

H

EADPHONES

EADPHONES

 

 

SAFETY

SAFETY

 

 

WARNIN

WARNIN

G

G

Contain  important  information  and 

use

useful  tips

 

on  headphones  outputs  and  monitoring 

levels. 

!

Summary of Contents for exodus atom mxr 808A

Page 1: ...GECKO EXODUS ATOM MXR 808A www geckomusic net www geckomusic net OWNER S MANUAL OWNER S MANUAL...

Page 2: ...other A grounding type plug has two blades and a third grounding prong The wide blade or the grounding prong is provided for your safety If the provided plug does not fit into your outlet consult an e...

Page 3: ...To ensure against potentially dangerous exposure to high sound pressure levels it is recommended that all persons exposed to equipment capable of producing high sound pressure levels use hearing prote...

Page 4: ...d at a fraction of a premium Our engineering team is constantly doing research and development to meet this objective We thank God that by HIS grace we have succeeded in developing the revolutionary C...

Page 5: ...e GECKO EXODUS ATOM MXR 808A active C R I S T A L Audiophile mixing console We recommend that you take a moment and read through the manual as it provides information that will assist you in using you...

Page 6: ...MXR 808A is ideal for whatever your application may be education sporting and worship events meetings seminars and presentations gigs at parties small clubs and coffee houses quality home and studio a...

Page 7: ...one of these connectors but you must not use both at the same time Please connect to only one of these connectors on each channel 2 GAIN CONTROL This control adjusts the sensitivity of both MIC XLR a...

Page 8: ...he channel sends to the AUX bus This knob should generally be set close to the position NOTES This control allows you to output the signal to the AUX bus regardless of the setting of the channel fader...

Page 9: ...icrophones To avoid damage to speakers be sure to turn OFF amplifiers or powered speakers before turning this switch ON or OFF 12 ST PFL SWITCH With the ST PFL switch unpressed the overall ST STEREO o...

Page 10: ...CA type output connectors By connecting these connectors to an external recorder you can record the same signal that is being output from the ST STEREO OUT L ODD and R EVEN connectors NOTES The mixing...

Page 11: ...MXR 808A Active Audiophile Mixing Console Plug the other end into a standard wall power outlet The fused IEC AC receptacle protects the mixing console from possible electrical hazards caused by power...

Page 12: ...microphones and instruments be sure that all devices are turned OFF Also be sure that all of the mixing console s channel faders and master control faders are set all the way down 2 For each connecti...

Page 13: ...icators AUX Bus MAIN STEREO Bus AUX Bus PHONES Bus Amplifier Rated Output 4 200W per Channel 2 Tier C R I S T A L Audiophile Class H Amplifier Protections Mid Point DC Drift Short Circuit ISC Open Cir...

Page 14: ...ice manuals 4 Connection or operation of the unit in any way that does not comply with the technical or safety regulations applicable in the country where the product is used 5 Damages defects caused...

Page 15: ...freight and packing Such costs will also be invoiced separately when the buyer has sent in a written repair order WARRANTY RIGHTS This warranty is exclusive and extended to the original buyer and is...

Reviews: