13

12

in.k450

in.k450

Pump 2 key

Press 

Pump 2

 key to turn Pump 

2 on. Press a second time to 

turn pump off. 

A built-in timer automatically 

turns pump off after a  20 

minute period, unless pump 

has been manually deactivated 

first.

Light key 

Press 

Light

 key to turn light on 

Subsequent presses turn lights 

on and off while changing 

colors.

A built-in timer automatically 

turns light off after a period 

of 2 hours unless it has been 

manually deactivated first.

Up/Down keys

Use 

Up

 or 

Down

 key to set 

desired water temperature. 

The temperature setting will 

be displayed for 5 seconds to 

confirm your new selection.

The "Set Point" icon indicates 

that the display shows the 

desired temperature, NOT the 

current water temperature!

Pump 3 Key (Blower)  

First press

Pump 3 ON, Blower OFF

Second press:

Pump 3 ON, Blower ON

Third press:

Pump 3 OFF, Blower ON

Fourth press:

Pump 3 OFF, Blower OFF

A built-in timer automatically 

turns blower off after a 20 

minute period, unless blower 

has been manually deactivated 

first.

functions and user instructions

functions and user instructions

On/Off key

Depending on the spa manu-

facturer, this key may have 

different functions: On/Off, 

Standby mode or quick enable 

of the Economy mode.

On/Off Mode

By default, the system is always 

on. Press and hold 

On/Off

 key 

for 5 sec. (or Press and hold 

Pump 1

 key for 5 sec.) to shut the 

system down for 30 minutes. 
The display will toggle between 

the “OFF” message and water 

temperature. Press On/Off key 

to restart the system before the 

expiration of the 30 minutes delay. 

Pump 1 key 

Press 

Pump 1

 key to turn Pump 

1 on at low speed. Press a 

second time to turn pump to 

high speed (with a dual-speed 

pump). A third time turns  

pump off.

A built-in timer automatically 

turns pumps and blower off 

after a period of 20 minutes, 

unless pump has been 

manually deactivated first.

Summary of Contents for Aeware3 in.k450

Page 1: ...in ye in k450 in stream user instructions and functions instructions d utilisation et fonctions ENGLISH FRENCH...

Page 2: ...IN THIS UNIT TO PREVENT ELECTRIC SHOCK HAZARD AND OR WATER DAMAGE TO THIS CONTROL ALL UNUSED RECEPTACLES MUST HAVE A DUMMY PLUG THIS CONTROLLER MUST NOT BE INSTALLED IN PROXIMITY OF HIGHLY FLAMMABLE M...

Page 3: ...TRICAL CODE IN EFFECT AT THE TIME OF THE INSTALLATION Electrical wiring North American model in ye Lamp test All the segments and LEDs are lighting up Software revision Revision of the software Low le...

Page 4: ...rected to ensure proper functioning of the system Both the error code and the water temperature are alternatively displayed Allerrorscodeswillbedisplayed onthe keypad display FLO The system did not de...

Page 5: ...9 8 in k450 overview in k450 forin yespasystems user instructions and functions...

Page 6: ...element is cooling down or 3 not enough current available to start heater Light icon The Light icon lights up when the light is on The icon s number of rays is proportional to the light s intensity Sm...

Page 7: ...ON Third press Pump 3 OFF Blower ON Fourth press Pump 3 OFF Blower OFF A built in timer automatically turns blower off after a 20 minute period unless blower has been manually deactivated first functi...

Page 8: ...emperature reading if required the system automatically turns the heater on to reach and maintain water temperature at Set Point Cooldown Afterheatingthe spawaterto the desired Set Point the heaterist...

Page 9: ...g Bluetooth technology only and will not work when AUX is selected as the source Turning power on off When connected to a power source the unit will automatically be ON Pressing and holding the Play P...

Page 10: ...u are using 2 In these settings turn Bluetooth on if it is not already 3 Choose Gecko in stream from the list of available devices 4 When prompted enter 5555 as the password Your device should now be...

Page 11: ...21 20 in chant in chant in stream in stream in ye in k450 in stream instructions d utilisation et fonctions...

Page 12: ...OUR PR VENIR TOUT RISQUE DE CHOC LECTRIQUE ET OU DE D G TS D EAU TOUTES LES FICHES NON UTILIS ES DOIVENT POSS DER UNE FICHE SANS R SISTANCE DE CHARGE CET APPAREIL NE DOIT PAS TRE INSTALL PROXIMIT DE M...

Page 13: ...blage lectrique mod le in ye nord am ricain Test des voyants Tous les segments et les voyants DEL sont allum s R vision de logiciel R vision de logiciel S lection de configuration interne Configuratio...

Page 14: ...rainsi quelatemp rature de l eau s affichent en alternance Tousles codes d erreur s affichent sur le clavier decommande FLO Le syst me ne d tecte aucune pression dans les tuyaux lorsque la pompe princ...

Page 15: ...29 in k450 in k450 poursyst mesdespasin ye Instructions d utilisation et fonctions...

Page 16: ...n Il clignote lorsque 1 il y a une demande de chauffage mais que le syst me n a pas encore activ le chauffe eau 2 le chauffe eau est hors fonction et que l l ment refroidi ou 3 il n y a pas assez de c...

Page 17: ...latemporisation de30minutes Touche Pompe 2 Appuyez sur la touche Pompe 2 pour d marrer la pompe 2 et une deuxi me fois pour l arr ter La pompe s arr tera apr s une p riode pr d termin e sauf si vous l...

Page 18: ...o xx repr sente le nombre de cycles de filtration par jour jusqu 4 Modifiez la valeur affich e au moyen des touches Up Down Unit de temp rature La temp rature de l eau peut tre affich e en Fahrenheit...

Page 19: ...ot de la technologie Bluetooth il doit tre connect que les fonctionnalit s fonctionnent Veuillez noter que les fonctions Lecture Pause et Changement de piste s appliquent aux appareils dot s de la tec...

Page 20: ...acement des r glages d pend de l appareil que vous utilisez 2 Dans ces r glages activez la technologie Bluetooth si ce n est d j fait 3 S lectionnez l option Gecko in stream dans la liste d appareils...

Page 21: ......

Reviews: