Device info
Menu item
[EN]
[DE]
Description
Version
70
[TypeNo]
[Modell-Nr]
Article number.
Indicates the article number of the control electronics (does not apply if the
control electronics have been replaced).
[...]
71
[SWVersion]
[SWVersion]
Software version.
Indicates the software version of the control electronics (e.g. [0312] =
version 3.12).
[...] XXZZ
72
[SerialNo]
[Serien-Nr]
Serial number.
Displays the serial number of the current control electronics.
[...]
73
[ManufDate]
[ProdDatum]
Manufacturing date.
Displays the manufacturing date of the control electronics. Does not apply
if the control electronics have been replaced (e.g. [1015] = calendar
week 10, 2015).
[...] WWYY
74
[TypePower]
[Netz/Batt]
Type of power supply.
Indicates whether it is a mains-operated (AC) or a battery-operated (DC) or
generator-operated (DC) urinal flush control.
DC = [0]
AC = [1]
75
[Battery%]
[Batterie%]
Battery capacity.
Displays the current battery capacity in %. At 10%, replace batteries or
charge rechargeable battery.
[...] %
Selecting the flush mode
Activating the interval flush
The interval flush [IntFlush] [IntervSp] is activated with menu item 30. It flushes after the last use once a
certain interval has elapsed [IntervalT] [IntervalZ] (menu item 44). The interval is restarted with every use.
The flush time is determined by [IntFlushT] [IntervSpZ] (menu item 43).
W
>,QWHUYDO7@
!>,QWHUYDO7@
>,QW)OXVK7@
>)OVK7LPH@ >)OVK7LPH@
>)OVK7LPH@
>,QWHUYDO7@
>,QWHUYDO7@
22
54043198642350731 © 01-2021
967.135.00.0(05)