Parameters
Menu item
[EN]
[DE]
Description
Application
Adjustment
range
Factory setting
40
[FlshTime]
[Spülzeit]
Set flush time.
Determines the duration of the
flush after one use.
Improving the flushing out
of the urinal ceramic,
observing water
consumption.
1–15 s [...]
7 s [7]
41
[DetectT]
[VerweilZ]
Set detection time.
Determines the minimum
detection time within the
detection range to be
recognised as a user.
Preventing flushes due to
unintentional entry into
the detection range.
3–15 s [...]
7 s [7]
42
[DelFollwF]
[FolgVerzö]
Set delay of follow-up flush.
Is active when menu item 34
“Activate follow-up flush” is
[ON] [EIN].
–
1–24 h [...]
2 h [2]
43
[IntFlushT]
[IntervSpZ]
Set the flush time for the
interval flush.
Is active when menu item 30
“Activate interval flush” is [ON]
[EIN].
–
3–180 s [...]
5 s [5]
44
[IntervalT]
[IntervalZ]
Set the flush interval for the
interval flush.
Is active when menu item 30
“Activate interval flush” is [ON]
[EIN].
–
1–168 h [...]
24 h [24]
45
[CleanTime]
[ReiniZeit]
Set cleaning time.
Defines the duration for which
the flush is suppressed when
menu item 26 [CleanMode]
[Reinigung] is started.
–
1–16 min [...]
10 min [10]
46
[DetectRng]
[Erfassdis]
Set detection range.
Optimising user recog-
nition.
0–4 [...]
[4]
47
[HybFlshT]
[HybFlshT]
Set flush time for the hybrid
mode.
Is active when menu item 37
“Activate hybrid mode” is [1] or
[2].
–
1–15 s [...]
7 s [7]
48
[HybTimOut]
[HybTimOut]
Set time-out for the hybrid
mode.
Is active when menu item 37
“Activate hybrid mode” is [1].
–
5–720 min [...] 60 min [60]
49
[HybIntT]
[HybIntT]
Set interval for the hybrid
mode.
Is active when menu item 37
“Activate hybrid mode” is [2].
–
10–1440 min
[...]
1440 min
[1440]
50
[PurgFlshT]
[PurgFlshT]
Set flush time for the purging
flush.
Is active when menu item 38
“Activate purging flush” is [ON]
[EIN].
–
3–30 s [...]
12 s [12]