4
Open the solenoid valve using the Geberit
Service Handy. → See "Make settings using
the Geberit Service Handy", page 33,
menu item 20.
5
Make sure that hot water (70°C) has run for
at least 3 minutes. Check with a
thermometer.
6
Close the solenoid valve.
7
Reactivate temperature limitation. Close the
hand wheel and set the desired temperature
(20–42°C).
ï
ࣜp$
✓ The colour in the inspection window
changes to blue.
8
Test the water temperature.
9
Mount the cover plate. → See figure
sequence
4
Replacing the functional unit
1
Detach the cover plate. → See figure
sequence
1
2
Close both shut-off units or angle stop
valves. → See figure sequence
2
3
Actuate the flush to relieve the pressure.
4
Demount the control electronics.
5
Disconnect all cables.
6
Remove the power supply cable from its
bracket and demount the power supply unit,
battery compartment or rechargeable
battery.
Summary of Contents for Piave
Page 1: ...971 197 00 0 00 GEBERIT WASHBASIN TAPS PIAVE AND BRENTA MAINTENANCE MANUAL...
Page 45: ...99079193583897099 03 2022 971 197 00 0 00 45 1 1 A 2 45 1 B 2 46 1 C 2 46 1 D 2 47 1 A 1 2...
Page 46: ...46 99079193583897099 03 2022 971 197 00 0 00 1 B 1 NN 2 1 C...
Page 47: ...99079193583897099 03 2022 971 197 00 0 00 47 1 D 1 2 1 2 1...
Page 48: ...48 99079193583897099 03 2022 971 197 00 0 00 2 3 4 3 1 2...
Page 49: ...99079193583897099 03 2022 971 197 00 0 00 49 3 4 4 4 A 2 50 4 B 2 50 4 C 2 51 4 D 2 51...
Page 50: ...50 99079193583897099 03 2022 971 197 00 0 00 4 A 1 2 NN 4 B 1 2 NN...
Page 51: ...99079193583897099 03 2022 971 197 00 0 00 51 4 C 4 D 1 1 2...