EN
Operation
Troubleshooting
Malfunction
Cause
Rectification
Water does not run
Water supply interrupted
▶ Restore the water supply.
Thermostatic cartridge
defective
▶ Replace the thermostatic
cartridge. → See
"Replacing the
thermostatic cartridge",
page 17.
Basket filter clogged
▶ Clean the basket filter.
Check valve defective
▶ Replace the check valve.
→ See "Replacing the
check valve", page 16.
Scald protection was
triggered
▶ Restore the cold water
supply.
Water too hot
Cold water shut off
▶ Open the angle stop valve
for cold water.
Water temperature set incor-
rectly
▶ Reset the water
temperature. → See
installation manual
968.642.00.0.
Thermostatic cartridge
defective
▶ Replace the thermostatic
cartridge. → See
"Replacing the
thermostatic cartridge",
page 17.
Basket filter clogged
▶ Clean the basket filter.
Check valve defective
▶ Replace the check valve.
→ See "Replacing the
check valve", page 16.
14
18014402994624651-1 © 10-2018
968.643.00.0 (01)