background image

Prerequisite

The status LED on the control panel
lights up green.

At the push of a button, the display
shows [Replace filter] on the rear side of
the remote control.

1

Bend the catch spring gently to the
side to unfasten the ceramic
honeycomb filter. At the same time,
remove the used filter from the
bracket.

2

Insert the new filter.

✓ The catch spring is used to fasten

the new filter.

3

Launch the [Care and maintenance]
main menu using the buttons on the
rear side of the remote control.

Care and maintenance

4

Use the <down> arrow key to select
the [Filter replaced?] menu item.

Filter replaced?

no

yes

5

Use the arrow keys to select <yes>.

Result

✓ Odour neutralisation will now function

again.

63050395945953803 © 05-2019
966.983.00.0(04)

43

Summary of Contents for AQUACLEAN MERA CLASSIC

Page 1: ...GEBERIT AQUACLEAN MERA CLASSIC USER MANUAL...

Page 2: ......

Page 3: ...erit AquaClean app 14 Switching on the device 15 Switching off the device 16 Restore to factory settings 16 How to use the device 17 Getting started 17 Using the anal shower 17 Switching the oscillati...

Page 4: ...eshooting 38 Troubleshooting 38 The shower toilet is without function 39 Other functional errors 40 The remote control is without function 41 Replacing the remote control battery 42 Re assigning the r...

Page 5: ...area for cleaning the outer vaginal area for odour extraction for installation in heated indoor areas for connection to the drinking water system for operation with water from reverse osmosis systems...

Page 6: ...ain any components for the user to service or repair Do not perform any changes or additional installations Modifying the device runs the risk of fatal danger Repairs may only be carried out by author...

Page 7: ...it reserves the right to make changes in terms of further development A current version of this and other documents is available online www geberit com Explanation of warning notes Warning notes are p...

Page 8: ...signal word denotes a hazard with a low degree of risk which if not avoided could result in minor or moderate injury ATTENTION The signal word denotes a hazard which if not avoided may result in mater...

Page 9: ...ray arm position spray arm with oscillating motion extendible Lady shower nozzle integrated into the spray nozzle with individual spray arm position automatic shower arm cleaning before and after each...

Page 10: ...on 4 Lateral control panel with status LED 5 Dryer arm with dryer nozzle 6 Spray arm with spray nozzle and Lady shower nozzle 7 Ceramic honeycomb filter art no 242 999 00 1 8 Spray shield 9 Geberit Aq...

Page 11: ...0HUD RPIRUW 3 WD 9 03D 1 Filling opening with plug for Geberit AquaClean descaling agent 2 Specification plate with serial number 3 Design cover with magnet 4 Power switch 63050395945953803 05 2019 96...

Page 12: ...of the remote control 1 Shower button start and stop the spray functionality stop the dryer functionality and Lady shower 2 buttons decrease or increase the spray intensity 3 left right arrow keys set...

Page 13: ...D display 3 up down left right arrow keys Lateral control panel The shower toilet functions of the device can be operated from the lateral control panel on the shower toilet 1 up down buttons decrease...

Page 14: ...w descaling It is not possible to use the shower toilet for the duration of the descaling procedure Flashes orange Water replacement is being carried out See Automatic water replacement page 30 Geberi...

Page 15: ...ch on procedures 1 Open the design cover 2 Turn on the power switch to start initialisation The blue status LED flashes during initialisation 3 Close the design cover Result When the blue status LED g...

Page 16: ...switch 4 Close the design cover Restore to factory settings Prerequisite You want to reset your personal settings and restore the factory settings as the basic settings Hold down the User profile butt...

Page 17: ...rsonal requirements you can change the basic settings and adapt these to your personal requirements When you get up from the WC seat ring the spray functionality deactivates the dryer functionality de...

Page 18: ...tion of the spray nozzle and the spray intensity must be selected so that the shower spray cannot penetrate the vagina Prerequisite You are sitting down on the WC seat ring 1 Press the Lady shower but...

Page 19: ...he spray arm position Prerequisite The shower procedure is running The spray arm position can be set in 5 levels Touch the left or right button The spray arm moves forwards or backwards Result The spr...

Page 20: ...ofile in the Geberit AquaClean app As long as you are in the detection range of the shower toilet you do not need to activate the user recognition in order to save your user profile in the Geberit Aqu...

Page 21: ...l Press any button on the rear side of the remote control to activate the display Pressing the up arrow key for more than 2 seconds returns the display to the Basic settings menu To save the modified...

Page 22: ...isplay Spray intensity Spray intensity of the anal shower Spray arm position Spray arm position of the anal shower Spray intensity Lady Spray intensity of the Lady shower Spray arm pos Lady Spray arm...

Page 23: ...value hard medium soft See Device descaling message page 37 System flush off on on The system flush starts as soon as a user is detected on the WC off The system flush starts before the shower procedu...

Page 24: ...isplay Note User profile selection Corresponds to the user profile buttons on the front side of the remote control Spray intensity Spray intensity of the anal shower Spray arm position Spray arm posit...

Page 25: ...erature regulation of the dryer Odour extraction off on on The odour extraction unit starts as soon as a user is detected on the WC off The odour extraction unit is deactivated System flush off on on...

Page 26: ...caling Descale device now no yes yes Start descaling See Descaling the device page 35 no Continue with the Filter replaced menu Device being prepared Now add the descaling agent Start descaling no yes...

Page 27: ...ra Classic Type equipment version Article number 146 xxx xxx Geberit article number Serial number GBxxxxxxxxxx Device serial number required in case of service Commissioning date dd mm yyyy Date the d...

Page 28: ...ay nozzle page 33 Rinse the spray nozzle under running water to remove foreign substances Monthly Clean the WC ceramic appliance with Geberit AquaClean cleaning agent See Cleaning the flushing area of...

Page 29: ...itable cleaning agents Skin friendly Cleaning agents are permitted to have a low acid content e g heavily diluted citric acid Low foaming Liquid Water dilutable Symbol Suitable cleaning equipment Soft...

Page 30: ...isinfection Observe the safety notes from the manufacturer when handling hazardous substances Type of disinfection Disinfection procedure Wet wipe disinfection For use on smooth surfaces that can be r...

Page 31: ...asily for simple cleaning Be careful not to scratch the surface of the WC seat Always place the components on a soft non scratching underlay 1 Place the WC seat ring in the vertical position 2 Slide t...

Page 32: ...ing Be careful not to scratch the surface of the WC seat Always place the components on a soft non scratching underlay 1 Open the design cover 2 Open the WC lid 3 Lift the WC lid vertically out of its...

Page 33: ...WC seat ring in the vertical position 3 Press the up button and the Shower button at the same time The spray arm extends fully 4 Twist the spray arm in any direction and remove it 5 Pull out the spray...

Page 34: ...rear side of the dryer arm and pull out the dryer nozzle 12 Clean the dryer arm and dryer nozzle Dry both parts carefully before re assembling the dryer arm 13 Replace the dryer nozzle if it can no l...

Page 35: ...descaling agent for descaling The descaling procedure should not be cancelled after filling the descaling agent because it would otherwise be flushed away unused The display shows Device is flushing P...

Page 36: ...e insert the plug 9 Remove splashes of descaling agent immediately with a damp cloth 10 Close the design cover 11 Use the arrow key to start the descaling procedure Start descaling no yes A status mes...

Page 37: ...messages and to carry out the necessary fault clearance for each message Cause Message Fault clearance Regular descaling at least once a year The status LED on the control panel flashes blue red The d...

Page 38: ...to demonstrate a fault or still does not work as normal Test the status LED on the lateral control panel See Status LED on the lateral control panel page 14 3 Steps 1 and 2 have been carried out The...

Page 39: ...Description of problem Cause Fault clearance The fuse or residual current device in the electrical distributor trips once Malfunction has occurred Replace or reset the fuse in the electrical distribu...

Page 40: ...42 The spray arm or dryer arm is not functioning correctly Malfunction has occurred Switch off the device See Switching off the device page 16 Wait 30 seconds Switch on the device See Switching on th...

Page 41: ...ns unresponsive when buttons are pushed Pairing unsuccessful Re assign the remote control See Re assigning the remote control page 42 Result The display shows Pairing ok The remote control is unable t...

Page 42: ...e control Press the button on the remote control and the up button on the lateral control panel for approx 30 seconds until Pairing ok appears on the display Result The shower toilet can be controlled...

Page 43: ...me remove the used filter from the bracket 2 Insert the new filter The catch spring is used to fasten the new filter 3 Launch the Care and maintenance main menu using the buttons on the rear side of t...

Page 44: ...projects around the world Ecodesign ecobalance The basis for sustainable products is formed by a systematic innovation process in which product materials and functional principles are chosen that are...

Page 45: ...es to which equipment can be returned can be requested from the relevant Geberit sales company Constituents This product conforms to the requirements of Directive 2011 65 EU 2011 06 08 Directive on th...

Page 46: ...entitled to assert more extensive claims against Geberit on the basis of this warranty 3 Claims can only be made under the warranty if a the product has been installed and put into operation by an ins...

Page 47: ...5 Water temperature 34 40 C Operating temperature 5 40 C Flow pressure 50 1000 kPa 0 5 10 bar Minimum flow pressure 50 kPa 0 5 bar Calculated flow rate 0 03 l s Maximum load WC seat 150 kg 1 The Blue...

Page 48: ...3867 800 F 385 1 3867 801 www geberit hr HU Geberit Kft 1117 Budapest Al z utca 2 T 36 1 204 4187 www geberit hu IT Geberit Marketing e Distribuzione SA Via Gerre 4 CH 6928 Manno T 41 91 611 92 92 F...

Reviews: