EN
Maintenance
Maintenance regulations
Interval
Maintenance work
Regularly (before use, at the
start of the working day)
▶ Check the pressing tool for externally visible defects and
damage that could affect safety, particularly leaking
hydraulic oil.
▶ Clean and lubricate the pressing tool.
▶ Clean pressing attachments and check for defects,
particularly for cracks in the material.
▶ Lubricate the pressing attachments. → See user manual
for the pressing attachments in question.
After one year at the latest, in
accordance with the informa-
tion on the service sticker.
▶ Have an authorised repair shop check the press capacity
and the state of wear.
Cleaning and lubricating the
Geberit pressing tool
ATTENTION
Damage to the device from moisture
▶
Never clean the pressing tool with
water or other liquids.
1
Clean the roller drive, roller drive
guide and retaining pin of the
pressing tool.
2
Use a brush to remove dirt.
CAUTION
Harmful substances
▶
Observe the safety notes of
the lubricant used.
3
Lubricate the roller drive, roller drive
guide and retaining pin with
BRUNOX® Turbo-Spray®.
4
Wipe away excess lubricant using an
absorbent cloth.
27021600880296075-1 © 02-2018
968.243.00.0 (00)
29