Setting the flush time manually
1
2
3
For mains-operated urinal flush control:
disconnect the plug connection between
the control and the power supply unit for at
least 20 seconds and then reconnect it.
For battery-operated urinal flush control:
disconnect the plug connection between
the control and the battery for at least
20 seconds and then reconnect it.
4
Within five seconds hold your hand around
5 cm away from and in front of the control.
The new flush time lasts as long as you keep
your hand in front of the control, up to a
maximum of 15 seconds.
Result
A flush sequence is actuated. The flush time that
has just been set is confirmed by flashing. The
number of flashes corresponds to the length of the
flush time in seconds.