In te rf ac es • In fr ar ed In te rf ac es
8
Ge BE E + F Gm bH • ww w .oe m- pri nte r .co m • SM AN -E- 471 -V2 .3 • The rm al Pri nte r GPT -43 78 / 437 9
The following pr otocols can be used:
• IrDA:
IR LPT (printer service)
IR COMM 9 wir e (optional)
Also see: www .ir da.or g
• G e B E - I R :
Simple, err or -pr oof, bidir ectional,
dot to dot IR-pr otocol.
GeBE Doc.No. MAN-D-394
• HP-IR:
Unidir ectional IR transmission
GeBE Doc.No. MAN-D-416
All standard versions of the printer have the hardware
for an IR transmitter/receiver installed, so the protocols
GeBE-IR and IrDA are available for all standard printers
of the series GPT-437x.
The inter nal IR tranceiver is installed dir ectly below the
r ed foil window (10). The GPT -4379 has an LED next to
the transceiver that signals any IR communication. It is
important to consider that infrared transmissions only
work "at sight". The radiation angle is about +/-15 de-
grees. The transfer distance, which also strongly de-
pends on the efficiency of the opposite side, is about
1.0 meter. It can be expanded to < 3 meters by in-
stalling a booster-IR LED.
Use of the Sleep Mode
In the setting "IrDA "or "GeBE IR", the IR r eceiver will
even be active in the sleep mode, so the device will not
have to be switched on explicitly for printing. The po-
wer consumption of the printer is only about 25µA in
this mode. However , the printer should still be tur ned
of f during long periods of inactivity .
GeBE -IR Pr otocol
The GeBE-Ir pr otocol is a simple, err or pr otected infra-
r ed pr otocol. The data transmission is pr ocessed in
CRC pr otected blocks.
With each transmission confirmation, the printer status
is sent back to the host.
The implementation is easy to r ealize. The pr otocol is
disclosed.
5.2 Infrar ed Interfaces
IrDA Pr otocol
In the menu setting, the selected baud rate r epr esents
the maximum baud rate. If 57,600 baud is selected, for
example, the printer will start to communicate with
9,600 baud and then switch up to 57,600 or 38,400
baud, depending on the transmitter .
The maximum baud rate of 115,200 should only be r e-
duced, if transmission pr oblems occur .
When an infrar ed transmission is interrupted, the printer
will look for the transmitting master device for about 20
seconds in or der to complete the transmission. After
that, the stack is r eset, and new inquiries ar e answer ed.
Driver for IrDA
Windows 98 / ME / NT / 2000 / XP
Driverfor Windows you can find on our W ebsites.
WIN CE , P ALM OS , SYMBIAN Serie 60
Driver for this systems you find at:
www .Bachmannsoftwar e.com
For pocke tPCs Bachmann of fers an application (Print-
boy) for printing p.e. out of Pocket W or d.
IrCom m Serv ices
Unco oked Serv ices
Cook ed Serv ices
IrLPT
3-wir e Raw
Cent ronic s
IEEE 1284
3 - wire
9 - wire
IrDA Data Specification
Radiation output
Booster radiation output
Min. input radiation intensity
Max. input radiation intensity
Peak wave length
Complies: IrDA V1.0 Standard Power SIR
min
40
max
100
100
150
4
500
870
mW/sr
On-axis
mW/sr
W/cm2
additional
v<(±15° )
mW/cm2
nm
v<(±15° )
Peak wave length booster LED
Safety
Range
Range booster LED
Complies with IEC 825-1 class 1 (EN 60825) eye safety specifications
880
0,01
0,05
1
< 3
IrDA
Interface parameters
GeBE-IR
Interface parameters
IrDA: automatic setting in accordance with IrDA ; 9,600, 38,400,
57,600, or 1 15,200 Baud
GeBE IR-Protocol: 9,600; 38,400; 57,600; or 1 15,200 baud,
8 data bits, non parity , 1 stop bit
nm
optional
m
m
optional