Technical data: Ambient temperatures
Designation
Description
Valve
0 to 45 °C (32 to 113 °F), standard
< 0 °C (32 °F): Use control air with low dew point.
Protect valve rods against freezing.
< −15 °C: no solenoid valves in the control top
< +50 °C: no solenoid valves in the control top
Proximity switch
-20 to +80 °C (-4 to +176 °F)
Control top T.VIS M-20, M-15, A-15, P-15
-20 to +55 °C (-4 to +131 °F)
Product temperature and operating temperature
depending on the sealing material
Technical data: Compressed air supply, product pressure
Designation
Description
Air hose
●
Metric
Material PE-LD
Outside Ø 6 mm
Inside Ø 4 mm
●
Inch
Material PA
Outside Ø 6.35 mm
Inside Ø 4.3 mm
Control air
acc. to ISO 8573-1
●
Solid particle content:
Quality class 6
Particle size max. 5 µm
Particle density max. 5 mg/m
3
●
Water content:
Quality class 4
max. dew point +3 °C
If the unit is used at higher altitudes or at low am-
bient temperatures, the dew point must be adap-
ted accordingly.
●
Oil content:
Quality class 3
preferably oil free
max. 1 mg oil to 1 m
3
air
Control air pressure
6 bar (87 psi), max. 8 bar (116 psi) configuration
with standard drive
Alternative combinations of product pressure and
control air pressure on request
Product pressure
5 bar (72.5 psi) configuration with standard drive
max. 10 bar (116 psi) configuration with corre-
spondingly designed actuator
> 10 bar (145.0 psi) for static applications and on
request
3.2 Technical data - 29 / 104
Summary of Contents for VARIVENT X R Series
Page 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 104...
Page 12: ...12 104 1 4 Declarations of conformity 0000000881 001 EN GB...
Page 40: ...40 104 5 5 Checking the pneumatic connection 0000000881 001 EN GB...
Page 44: ...44 104 7 3 Shutdown 0000000881 001 EN GB...
Page 88: ...88 104 9 7 Maintenance 0000000881 001 EN GB...
Page 90: ...90 104 9 7 Maintenance 0000000881 001 EN GB...
Page 98: ...98 104 12 2 Spare parts lists 0000000881 001 EN GB...
Page 103: ...13 2 List of abbreviations 103 104...