Table nominal width OD
Nominal width OD
X1 (mm)
X2 [mm]
1"
on request
on request
1.5"
27.5
95.5
2"
27.5
103.5
2.5"
27.5
113.5
3"
27.5
118.5
4"
20.5
137.5
6.5.5
Assignment of initiators
The assignment of the initiators is indicated by the LED in the housing. The
required assignments of the initiators, depending on the activation and reaching
the respective end position of the pig drive, are shown in the following table.
Assignment of initiators
Actuation
State D1.1
State D1.2
V3.1
assigned
not assigned
V3.2
not assigned
assigned
After actuation of V3.2
not assigned
not assigned
6.5.6
Securing the magnetic switch on the pig station housing
Fig.18
Carry out the following steps:
1.
Screw the threaded bushing (E3) onto the magnetic switch (E1).
2.
Secure the magnetic switch (E1) onto the magnetic switch holder (E) of the
pig station housing (7) from below using a nut.
3.
! No gaps or threads must be visible.
®
Done.
Assembly and installation
430BAL009974EN_3
23.07.2019
37