Technical data: Pig cleaning station
Designation
Description
Installation position
The installation position of the pig
cleaning station can be standing
upright, overhead, horizontal or
diagonal. However, the pig cleaning
station must be arranged in such a
way that the pig station housing and
the pipe system can be safely emptied,
i.e. in a horizontal and diagonal
position, the side pipe connection
supports must be directed downwards.
Product pressure
DN 25 ...80: 16 bar (232 psi)
DN 100: 10 bar (145 psi)
OD 1" ... 3": 16 bar (232 psi)
OD 4": 10 bar (145 psi)
Flow speed
max. 3 m/s
Pig velocity of impact
max. 0.5 m/s
Technical data: Ambient temperatures
Designation
Description
- Pig cleaning station
0 to 45 °C (32 ... 113 °F), standard
< 0 °C (32 °F): use control air with a
low dew point. Protect piston rods
against freezing.
- Proximity switch
-30 to +85 °C (-22 ... +185 °F)
- Control top type T.VIS M-15, A-15
-20 to +50 °C (-4 ... +122 °F)
- Control top type T.VIS P-15
-25 to +70 °C (-13 ... +158 °F)
Product temperature and operating
temperature
Depending on the sealing material
Technical data: Compressed air supply
Designation
Description
Air hose
- Metric
Material PE-LD
Outside Ø 6 mm
Inside Ø 4 mm
- Inch
Material PA
Outside Ø 6.35 mm
Inside Ø 4.3 mm