3.
Push the proximity switch holder (D) from above or below onto the cylinder
pipe (4) and set in accordance with table “Position of proximity switch holder”,
see Section 6.5.4, Page 36.
4.
Lock the proximity switch holder (D) with the screw (D2) and counter with the
nut (D3).
5.
Screw the initiators (D1) up to the stop and lock with the counter nut.
!
No gaps or threads must be visible.
®
Done
6.5.3
Initiator cabling
It must be possible to completely remove the pig actuator from the pig station
housing without loosening the initiator cabling. This means that the cable length
of the initiators must be dimensioned accordingly.
6.5.4
Position of proximity switch holder
Fig.17
Table nominal width DN
Nominal width DN
X1 [mm]
X2 [mm]
25
on request
on request
40
27.5
103.5
50
27.5
103.5
65
27.5
118.5
80
27.5
118.5
100
20.5
137.5
Assembly and installation
Electrical connections
430BAL009974EN_3
36