List of tools (in alphabetical order)
Tools
Figure
Intended Purpose
Material Number
GEA Aseptomag AG
Seeger circlip pliers
Inside diameter 40-100
mm,
angled tip, 90°
Fig.29
PA20 - 60
Remove/fit PA
0980.50108
S-12-0541
Shut-off valve Ø 6 mm
Fig.30
Inspection of metal
bellows
9999.10091
Socket wrench bit
a/f 13, square drive ½"
Fig.31
Valves
DN 10 - DN 100
Release divisible valve
discs
0980.00009
S-12-0663
10.5
Prior to disassembly
Prerequisite:
•
Make sure that while work is being performed on the open valve no process is
in operation in the area concerned.
Carry out the following steps:
1.
Drain all pipe system elements that lead to the valve and, if necessary, clean
or rinse, and also depressurize them.
2.
Shut off the control air supply.
3.
Disconnect the power supply.
®
Disassembly has been prepared.
10.6
Disassembling and Assembling the Valve
10.6.1 Disassembling the Valve
Tools required:
•
Hex socket key
•
Open end spanner
Maintenance
Prior to disassembly
430BAL012841EN_1
38
07.03.2018
Summary of Contents for Aseptomag ADV