background image

9

ge.com

Wall sleeve dimensions

Heavy-gauge galvanized  
steel with a baked enamel 
finish for outstanding  
protection and appearance.

RAB71A wall sleeve 

Heavy-gauge galvanized steel, with insulation. 
A-", B-1 /", C-1"

RAB77A4 wall sleeve

 (shown above) 

Molded SMC fiberglass-reinforced polyester compound. 
A- 1/8", B-1 7/8", C-1  1/"

Wall opening dimensions 

Add 1/" to A and C dimensions for all cutout sizes. 
RAB71 1 1/" min. H. x  1/" min. W. 
RAB71 available in 1", ", 8" and 1" depths. 
RAB77A 1 1/" min. H. x  /8" min. W.

Premium models

5800 series  

Highly featured microcomputer controls

B

C

A

Auto frost  

control monitor 

A special sensor monitors 

the roomside coil to  

prevent efficiency-robbing 

accumulation of frost  

during cooling cycle.

Electronic  

temperature limiting

 

Preset cooling and heating 

limits with 7 independent 

cooling and 7 heating 

limits—saves energy by  

preventing over-cooling or 

over-heating of rooms.

“Smartfan”  

fan cycle selection

 

Select fan cycle or fan 

continuous independently 

for heating and cooling.

Universal power cord 

Flexibility of heat  

applications. Each  

premium line Zoneline 

contains a bank of  

 heaters.

Microcomputer controls 

Electronic components 

for fast response and 

accuracy.

Rotary compressor 

With fewer moving 

parts than reciprocating 

models for quiet,  

reliable operation.

Easy-access filter  

(not shown) 

Two upfront filters  

are part of roomside 

cabinet for easy access 

and maintenance.

Cross-flow blower 

Quiet blower reduces 

annoying “Air rush” noise.

Reversible louver 

(not shown) 

May be reversed to 

provide an air discharge 

angle of 0 or 50 degrees 

off vertical with the 

removal of six screws.

3 position vent control 

(not shown) 

Opens vent. Provides up 

to 70 cfm of outdoor air. 

The closed position saves 

energy by recirculating 

conditioned room air.

Solid state  

thermostat control 

Provides better room  

temperature control  

vs. electromechanical  

temperature control 

device. 

Freeze Sentinel

 

Provides automatic  

protection against  

freezing by switching  

the unit to heat should  

the temperature of an 

unoccupied room drop 

to 1°F.

Heat Sentinel 

Provides automatic  

protection against  

overheating by switching 

on the unit to cool should 

the temperature of  

an unoccupied room 

reach 85°F.

Room occupancy  

sensor compatible

 

Ready for connection  

to room occupancy  

sensor system. 

Weather-protected  

electrical components

 

On inside of barrier.

Two fan motors 

(not visible) 

Separate motors for 

indoor and outdoor fans 

to assure quiet operation.

Touch pad controls 

With electronic control 

temperature display.  

Gives the user finer 

control over the 

temperature.

Reverse cycle defrost  

(not shown) 

Solid state sensor  

monitors frost build-up  

on outdoor coil. When 

frost is detected, the 

refrigerant flow is reversed 

to melt frost build-up. 

When completed, the 

refrigerant is reversed  

to the normal energy  

saving heat pump  

operation for additional 

heat pump operating hours.

Central desk  

control compatible

 

Ability to turn the unit  

“on” or “off” from a 

remote location.

Remote control  

compatible 

Ability to be controlled  

by a wall-mounted  

thermostat with high  

or low fan speed.

Electrical connection

0/08 volt units may be plugged into  
a receptacle. 5 volt units are provided  
with a junction box and require direct  
connection. (NEC Requires 5V Direct  
Connection.) See Architects and Engineers  
Design Data Manual for electrical  
connection information including use of  
sub-base for direct-connected units. Installation  
must comply with local electrical codes and regulations.

Ducted applications

900 and 900 series can be used with ductwork to heat or cool more 
than one room. RAK05 Duct Adapter is applied to top of case over air  
discharge. RAK01 Duct Extension is applied to right or left of adapter. 
Locally fabricated ductwork may be added to extend to maximum  
recommended distance of 15 feet.

For additional information on ducted applications, including special  
adapters for replacement units, refer to Architects and Engineers Design 
Data Manual.

Summary of Contents for Zoneline Premium AZ58H09D

Page 1: ...GE Zoneline packaged terminal air conditioners ...

Page 2: ... ...

Page 3: ...nd apartments All Zoneline units feature the exclusive GE Superseal system which minimizes energy usage by reducing air infiltration The result is maximum operating efficiency and a more comfortable room All Zoneline units are also very quiet thanks to a lower sound level and lower sound transmission The newest innovation in Zoneline units is the Dry Air 25 Series Similar to our Deluxe 2900 Series...

Page 4: ...its are equipped with microcomputer touch controls This feature gives the user better control over the temperature with a touch pad and an LED readout Optional corrosion treatment Deluxe Zoneline units can be ordered with special treatment to reduce the effects of corrosive environments Special treatments are placed on the outdoor coil and other components to extend the life of the unit Remote ins...

Page 5: ...om the air than standard GE packaged terminal air conditioners The Dry Air 25 is perfect for high humidity climates Available on 7000 9000 and 12000 BTU models Upfront filters For ease of cleaning all Zoneline units have interchangeable removable upfront filters made of long lasting nylon mesh thus assuring high performance and long life Electronic temperature limiting Heating and cooling temperat...

Page 6: ...of cleaning Long lasting nylon mesh Central desk control compatibility Remote thermostat capability Smartfan Fan cycle operation based on heat cool selection Deluxe Dry Air 25 series cooling with resistance heat Includes all features of 2900 series plus Removes 25 more moisture from the air than standard GE packaged terminal air conditioners Cool and dry air in less time than standard Zoneline mod...

Page 7: ...e control Standard Standard Standard Standard Fan Only setting 2 speed Hi Low Hi Low Hi Low Hi Low Indoor fan speed Hi Low Hi Low Hi Low Hi Low Cool heat only settings Hi Low Auto Hi Low Auto Hi Low Auto Hi Low Auto Staged heating 3 stage 3 stage Freeze Sentinel Standard Standard Standard Standard Heat Sentinel Standard Standard Standard Standard Temperature limiting Electronic 7 step Electronic 7...

Page 8: ...eating of rooms Smartfan fan cycle selection Select fan cycle or fan continuous independently for heating and cooling Solid state thermostat control Provides better room temperature control vs electromechanical temperature control device Freeze Sentinel Provides automatic protection against freezing by switching the unit to heat should the temperature of an unoccupied room drop to 41 F Heat Sentin...

Page 9: ...mperature control device Freeze Sentinel Provides automatic protection against freezing by switching the unit to heat should the temperature of an unoccupied room drop to 41 F Heat Sentinel Provides automatic protection against overheating by switching on the unit to cool should the temperature of an unoccupied room reach 85 F Room occupancy sensor compatible Ready for connection to room occupancy...

Page 10: ...ity RAK3153 3203 230 208 volt line cord connection kit RAK4157 4207 4307 230 208 volt universal power supply kit RAK5157 5207 5307 265 volt universal power supply kit 230 208 volt Line cord connected units LCDI Power Connection Kit RAK3153 RAK3203 RAK3303 Heater KW 2 55 2 09 3 45 2 82 5 00 4 09 Watts 2 550 2 090 3 450 2 820 5 000 4 090 BTUH 8 600 7 100 11 700 9 600 17 000 13 900 Amps 11 6 10 6 15 ...

Page 11: ...50 13 400 6 400 6 200 8 400 8 200 10 900 10 700 13 800 13 800 COP 3 6 3 6 3 6 3 6 3 4 3 4 3 2 3 2 3 7 3 7 3 6 3 6 3 4 3 4 3 2 3 2 Watts 520 505 695 675 950 925 1 275 1 245 505 490 685 670 940 920 1 265 1 235 Amps 2 4 2 6 3 2 3 5 4 3 4 7 5 8 6 3 2 4 2 5 3 2 3 4 4 3 4 7 5 7 6 2 Weight Net Ship 102 117 105 120 113 128 123 138 108 122 113 128 118 133 127 142 Sound Transmission Class STC 29 29 29 29 29...

Page 12: ...Solenoids Circuit Boards Auxiliary Controls Thermistors Freeze Sentinel Frost Controls ICR Pump Capacitors Varistors and Indoor Blower Bearing if any of these parts should fail due to a defect in materials or workmanship During this additional four year limited warranty you will be responsible for any labor and related service costs See written warranty for details The Zoneline chassis is identifi...