background image

Zoneline

®

 units are designed with innovative, universal 

components, and offer even greater installation flexibility 
than ever, whether in new construction, renovation or 
for replacement of old units. Unless specified by code, 
they require no sub-base and may be installed flush with 
finished floor. All models are adaptable to remote and 
central desk control. Zoneline units may even be placed 
in unusual locations, such as transom or common-area 
installations. The two lines, Deluxe and Premium, each 
with its own special blend of features, offer flexibility to 
meet each zone application. All units come with  
microcomputer controls.

Easy installation and flexibility of design

Wall sleeve (optional)

RAB71A (Shown)

RAB77A (SMC) (Not Shown)

Room cabinet

Deluxe 900 series 
cooling with resistance heat

• Digital controls 

- LED temperature display

  - Easy temperature selection 

- Tactile touch pads

• Two fan motors

  - Improved quiet sound levels

  - Higher efficiency
• Electronic temperature limiting

  - Helps reduce operating costs
• Optional corrosion treatment

  -  Reduces the effects of coastal  

environments

• Freeze Sentinel

  -  Protects unoccupied rooms from  

damage by freezing temperatures

• Heat Sentinel

  -  Reduces excessive temperatures  

in unoccupied room

• GE-exclusive Superseal

  - Increased room comfort

  - Energy savings
• Upfront filters

  - Ease of cleaning

  - Long-lasting nylon mesh
• Central desk control compatibility 
• Remote thermostat capability
• Smartfan

  -  Fan cycle operation based on  

heat/cool selection

Deluxe Dry Air 5 series 
cooling with resistance heat

Includes all features of 900 series, plus:
• Removes 5% more moisture from the  

air than standard GE packaged terminal  

air conditioners

• Cool and dry air in less time than standard 

Zoneline models

• Maintains comfort at slightly higher room 

temperatures

  - Helps reduce operating costs

  -  Provides comfort without overcooling 
• Corrosion treatment is standard
• Heat pipe is a separate sealed  

refrigerant system

  - No mechanical parts

  - No special maintenance required
• Helps maintain lower relative humidity  

in rooms

• Best suited for humid climates

Deluxe 900 series 
cooling with heat pump  
and resistance heat

Includes all features of 900 series, plus:
• Reverse cycle heating

  -  Energy savings over electric  

resistance heat

  - Significantly lower operating costs
•  Heat pump operation down to 5°F  

outdoor temperature

•  Three-stage thermostat for quicker  

heat recovery 

•  Optional factory-installed internal  

condensate removal (ICR) 

  - Minimizes need for drain systems
•  Heat pump and resistance heat can  

operate together

  - Better room comfort

  -  Helps reduce operating costs over  

all standard heat pump systems

• Reverse cycle defrost

  - Extends heat pump operation

  - May help lower operating costs
• Electric resistance heat lockout

  -  Lowers operating costs by restricting 

electric heat operation when outdoor 

temperature is above °F.

Summary of Contents for Zoneline Premium AZ58H09D

Page 1: ...GE Zoneline packaged terminal air conditioners ...

Page 2: ... ...

Page 3: ...nd apartments All Zoneline units feature the exclusive GE Superseal system which minimizes energy usage by reducing air infiltration The result is maximum operating efficiency and a more comfortable room All Zoneline units are also very quiet thanks to a lower sound level and lower sound transmission The newest innovation in Zoneline units is the Dry Air 25 Series Similar to our Deluxe 2900 Series...

Page 4: ...its are equipped with microcomputer touch controls This feature gives the user better control over the temperature with a touch pad and an LED readout Optional corrosion treatment Deluxe Zoneline units can be ordered with special treatment to reduce the effects of corrosive environments Special treatments are placed on the outdoor coil and other components to extend the life of the unit Remote ins...

Page 5: ...om the air than standard GE packaged terminal air conditioners The Dry Air 25 is perfect for high humidity climates Available on 7000 9000 and 12000 BTU models Upfront filters For ease of cleaning all Zoneline units have interchangeable removable upfront filters made of long lasting nylon mesh thus assuring high performance and long life Electronic temperature limiting Heating and cooling temperat...

Page 6: ...of cleaning Long lasting nylon mesh Central desk control compatibility Remote thermostat capability Smartfan Fan cycle operation based on heat cool selection Deluxe Dry Air 25 series cooling with resistance heat Includes all features of 2900 series plus Removes 25 more moisture from the air than standard GE packaged terminal air conditioners Cool and dry air in less time than standard Zoneline mod...

Page 7: ...e control Standard Standard Standard Standard Fan Only setting 2 speed Hi Low Hi Low Hi Low Hi Low Indoor fan speed Hi Low Hi Low Hi Low Hi Low Cool heat only settings Hi Low Auto Hi Low Auto Hi Low Auto Hi Low Auto Staged heating 3 stage 3 stage Freeze Sentinel Standard Standard Standard Standard Heat Sentinel Standard Standard Standard Standard Temperature limiting Electronic 7 step Electronic 7...

Page 8: ...eating of rooms Smartfan fan cycle selection Select fan cycle or fan continuous independently for heating and cooling Solid state thermostat control Provides better room temperature control vs electromechanical temperature control device Freeze Sentinel Provides automatic protection against freezing by switching the unit to heat should the temperature of an unoccupied room drop to 41 F Heat Sentin...

Page 9: ...mperature control device Freeze Sentinel Provides automatic protection against freezing by switching the unit to heat should the temperature of an unoccupied room drop to 41 F Heat Sentinel Provides automatic protection against overheating by switching on the unit to cool should the temperature of an unoccupied room reach 85 F Room occupancy sensor compatible Ready for connection to room occupancy...

Page 10: ...ity RAK3153 3203 230 208 volt line cord connection kit RAK4157 4207 4307 230 208 volt universal power supply kit RAK5157 5207 5307 265 volt universal power supply kit 230 208 volt Line cord connected units LCDI Power Connection Kit RAK3153 RAK3203 RAK3303 Heater KW 2 55 2 09 3 45 2 82 5 00 4 09 Watts 2 550 2 090 3 450 2 820 5 000 4 090 BTUH 8 600 7 100 11 700 9 600 17 000 13 900 Amps 11 6 10 6 15 ...

Page 11: ...50 13 400 6 400 6 200 8 400 8 200 10 900 10 700 13 800 13 800 COP 3 6 3 6 3 6 3 6 3 4 3 4 3 2 3 2 3 7 3 7 3 6 3 6 3 4 3 4 3 2 3 2 Watts 520 505 695 675 950 925 1 275 1 245 505 490 685 670 940 920 1 265 1 235 Amps 2 4 2 6 3 2 3 5 4 3 4 7 5 8 6 3 2 4 2 5 3 2 3 4 4 3 4 7 5 7 6 2 Weight Net Ship 102 117 105 120 113 128 123 138 108 122 113 128 118 133 127 142 Sound Transmission Class STC 29 29 29 29 29...

Page 12: ...Solenoids Circuit Boards Auxiliary Controls Thermistors Freeze Sentinel Frost Controls ICR Pump Capacitors Varistors and Indoor Blower Bearing if any of these parts should fail due to a defect in materials or workmanship During this additional four year limited warranty you will be responsible for any labor and related service costs See written warranty for details The Zoneline chassis is identifi...

Reviews: