8
Zoneline
®
Features
AZ
AZ
AZ
2800
800
5800
Enhanced Dehumidification — Dry Air 25
Optional
N/A
N/A
Cooling EER Range (20 Volts/265 Volts)
10.2 - 12.7
10.0 - 12.7
10.2 - 1.0
Heating COP Range (20 Volts/265 Volts)
N/A
.2 - .6
.2 - .6
Heat Source — Electric Resistance Heat
Standard
—
—
Heat Source — Heat Pump With Selectable
Full Time or On Demand Simultaneous/
Supplemental Resistance Heat
—
Standard
Standard
Staged Heating
—
Stage
Stage
Universal Heater — UPC*
Standard
Standard
Standard
Unit Controls
Rotary Knobs
Rotary Knobs
Touch Pad
Electronic Temperature Selection
(Slews Up & Down) with Digital Display
—
—
Standard
Unit Diagnostics
—
—
Standard
Highly Featured Microprocessor Controls
Standard
Standard
Standard-Plus
Electric Resistance Heat Lock-Out (above 46°F)
—
Standard
Standard
Automatic Emergency Heat
—
Standard
Standard
Heat Pump Defrost System
—
Reverse Cycle
Reverse Cycle
High Temperature Operation Protection
—
Standard
Standard
Quick Heat Recovery
—
Standard
Standard
Temperature Boost
Selectable
Selectable
Service Indicator
—
—
Temp Display Blinks
Fan Motors — Permanently Lubricated
2
2
2
2-Speed Outdoor Fan
Standard
Standard
Standard
Indoor Fan Speed Selections — HIGH/LOW
Standard
Standard
HIGH/LOW/AUTO
Fan Only Setting — HIGH/LOW
Standard
Standard
Standard
Fan Cycle Switch
“Smart Fan”
“Smart Fan”
“Smart Fan”
Constant-Run Fan
Selectable
Selectable
Selectable
Rotary Compressor
Standard
Standard
Standard
Automatic Compressor Restart Delay
Standard
Standard
Standard
Freeze Sentinel
™
Standard
Standard
Standard
Heat Sentinel
Standard
Standard
Standard
Indoor Coil Frost Control
Standard
Standard
Standard
Transfer Fan Connections
Standard
Standard
Standard
7-Step Electronic Temperature Limiting
Standard
Standard
Standard
Remote Control Capability with Wall Mounted Thermostat
Standard
Standard
Standard
Central Desk Control Capability
Standard
Standard
Standard
Energy Management System Interface with Load Shedding Option
Standard
Standard
Standard
Reversible Indoor Air Louvers 40º/50º
Standard
Standard
Standard
Up-Front Filters
Standard
Standard
Standard
Easy-Clean Air Discharge Area
Standard
Standard
—
Concealed Manual Vent Control
Standard
Standard
Standard
Ducted Installation Capability
RAK6052
RAK6052
—
Corrosion Protection (Standard on Dry Air 25)
Optional
Optional
Standard
Internal Condensate Removal (ICR) (Factory Installed Option.
Cannot be used in Corrosion Areas.)
N/A
Optional
Optional
*UPC — Universal Power Cord Connection (See pages 42 and 55).
265-volt units must be connected in a manner to meet National Electrical Code and all local codes.