9
Installation
Professional Gas Cooktops
Connect
Electrical
Step
6
Assemble
Burners,
Check
Ignition
7
Step
Igniter
Burner
Main Burner
Venturi (rear)
Air Shutter
Burner
Simmer Burner
Venturi (rear)
Simmer Burner
Venturi (rear)
Main Burner
Venturi (rear)
Igniter
Plug power cord into properly grounded
receptacle.
• Replace the burner bowls and burner caps.
• Adjustments should not be required, unless
vibration during transit or variations in local
gas supply make minor adjustments neces-
sary.
CAUTION: Burner adjustments must be made
by a qualified technician at the time of
installation. Extreme care should be used if
adjustments are made after installation.
• Burner flames should be blue and stable with
no yellow or yellow tips, excessive noise or
lifting of the flame from the burner. If any of
these conditions exist, check that the air
shutter or burner ports are not blocked. If
one of these conditions continues, adjust the
air shutter as required.
–If the flame is too yellow, there is
insufficient air flow, adjust the shutter
counterclockwise to increase air inlet.
–If the flame is noisy or tends to lift away
from the burner, there is too much air. Turn
the shutter clockwise to reduce air.