– 11 –
Timer
The timer is a double switch bank, with polarized
harness connectors. This insures that the correct
harness connector will only fit the mating switch
bank.
Some models have only one switch bank, check
mini-manual.
Timer motor and timer are NOT interchangeable
with the other timers. It is stocked as one com–
ponent, and repair parts are not available. The
mounting bracket is stocked as a separate part
and can be reused to install the replacement timer.
Timer cam charts and schematics are shown in
mini-manual located in the backsplash.
NOTE: LID SWITCH CAN BE ACCESSED BY
REMOVING DOOR AND LATCH ASSEMBLY
ON METER CASE AS SHOWN. USING A
PLASTIC PEN TO PREVENT SHOCK HAZARD,
HOLD DOWN LID SWITCH ACTIVATOR AND
THIS WILL ALLOW YOU TO RUN THE MACHINE
WITH LID UP FOR SERVICE.
WARNING! TAKE NECESSARY PERSONAL SAFETY
PRECAUTIONS TO AVOID PERSONAL INJURY DUE
TO SPIN BASKET RUNNING WITH LID UP.
DUST
COVER
MOTOR
SWITCH
LOCATING BOSS
TIMER IN
COIN BOX
Note:
Lid switch can be accessed by removing
door and latch assembly on meter case as
shown in illustration. Use a plastic pen to
prevent shock hazard. Hold down lid switch
activator and this will allow you to run the
machine with lid up for service.
WARNING!
Take necessary personal safety
precautions to avoid personal injury due to spin
basket running with lid up.