WavePro™ Breaker Catalog Number Guide
W
E
2
D
A
Q
D
1
2
3
4
5
6
7
Trip unit codes (See Table A)
TU function
Code
none X
LS
➁
A
LSG
➂
B
LSGZ1
➂
C
LSGZ2
➂
D
LSGD
① ➂
E
LSGDZ1
① ➂
F
LSGDZ2
① ➂
G
LI
➁
J
LIG
➂
K
LIGZ1
➂
L
LIGD
① ➂
M
TU function
Code
LIGDZ1
① ➂
N
LSI
➁
P
LSIG
➂
Q
LSIGX
① ➂
R
LSIGZ1
➂
S
LSIGZ2
➂
T
LSIGD
① ➂
V
LSIGDZ1
① ➂
W
LSIGDZ2
① ➂
Y
LSIX
Z
①
Not UL Listed
➁
Power+ available with LI, LS or LSI only
➂
GF is 3w/4w (See Note 1 below)
Rating
Sensor Plug
Code
none
X
60
①
1
80
2
150
100
3
125
4
150
5
150
①
5
200
6
400
225
7
250
8
300
9
400
A
300
①
9
800
400
A
450
①
B
500
C
Rating
Sensor Plug
Code
600
D
800
700
E
800
G
600
①
D
800
G
1600
1000
H
1100
①
J
1200
K
1600
M
750
①
F
800
①
G
1000
H
2000
1200
K
1500
①
L
1600
M
2000
N
Rating
Sensor Plug
Code
1200
K
3200
1600
M
2400
P
3200
S
1600
M
2000
N
4000
2500
Q
3000
R
3600
①
T
4000
V
3200
①
S
5000
4000
①
V
5000
①
W
①
Rating plug value not
available on Power+
trip unit
Usage
Code
AKD10/PBII/AV3 Access Equipment
WE
OEM Substructure
WS
Interrupting Capability/
Silver
Fuse Type
Code “L” Fuse
Standard
(ex. WPS)
1
High
(ex. WPH)
2
Extended
(ex. WPX)
3
OFLO only
4
300A
Class “J” fuse
A
350A
Class “J” fuse
B
400A
Class “J” fuse
C
450A
Class “J” fuse
D
500A
Class “J” fuse
E
600A
Class “J” fuse
F
800A
Class “L” fuse
G
5
1000A
Class “L” fuse
H
6
1200A
Class “L” fuse
J
7
1600A
Class “L” fuse
K
8
2000A
Class “L” fuse
L
9
2500A
Silver “L” fuse
M
800A “Welder”
limiter
N
1600A “Welder”
limiter
Q
2000A “Welder”
limiter
R
1000A “Welder”
limiter
Z
Frame
& Sensor Code
(See Note 1)
800
none
A
150
B
400
C
800
D
1600
none
E
800
F
1600
G
2000
none
H
2000
J
3200
none
K
3200
L
4000
none
M
4000
N
5000
5000
R
Trip Unit type
Code
none (non-automatic)
X
MVT Plus
A
MVT M (metering & communications) B
MVT PM (relaying, metering
& communications)
C
MVT Plus (w/special GF curve)
➃
D
MVT M (w/special GF curve)
➃
E
MVT PM (w/special GF curve)
➃
F
Power +
①
G
Power + (w/GF)
① ➂
H
Power + (w/Defeatable GF)
① ➁ ➂
J
Power + (w/targets)
①
K
Power + (w/targets & GF)
① ➂
L
Power + (w/targets &
Defeatable GF)
① ➁ ➂
M
①
Power + is not available for 5000A frame breakers
➁
Not UL Listed
➂
GF is 3w/4w (See Note 1 below)
➃
Not available on Type WS (OEM) breakers
Table A
L
= Long Time (LT)
S = Short Time (ST)
I
= Instantaneous (Inst)
G = Ground Fault (GF)
GD = Defeatable GF
X = Switchable ST or Inst OR
Switchable ST or Inst and GF
Z1 = Zone Selective Interlocking—GF
Z2 = Zone Selective Interlocking—
GF and ST
Note 1: If 4 wire GF is required then the "A-Disc" [character position 14] must
be selected and the 4th wire (neutral) sensor must be ordered separately.
Refer to DEP-080 Product Catalog.
Sensor = "none" for non-automatic breakers
Equipment Usage
Frame Sizes & Interrupting Rating
Trip Unit Type, Characteristics & Trip Rating
Fuse Link
S
on
T
Phase B
U
(not available
V
on Type WS
W
[OEM] breakers)
Y