WattStation™ Wall Mount User Manual
4
GE Energy
©2012 GE Company All Rights Reserved
•
Recommended mounting hardware for wood studs are 1/4" x 2" hex head lag bolts.
Recommended mounting hardware for concrete walls are 1/4" x 1-3/4" concrete hex screws or
1/4" x 1-7/8" concrete anchors
WARNING:
Danger of electrical shock or injury. Turn OFF power at the panelboard or load center before
working inside the equipment or removing any component. Do not remove circuit protective devices or
any other component until the power is turned OFF.
2.2.2 Installation
Step 1:
Carefully unwrap the packaging and make sure the following items are present:
-Wall Mounted WattStation unit
-Mounting wall bracket
-Key for WattStation mounting lock
WattStation Wall Mount User Manual
Torque Specification Table:
COMPONENT
TORQUE VALUE
TOLERANCE
M5 x 0.8 screw
30 in-lb
+/- 2 in-lb
#12 thread-cutting screw
30 in-lb
+/- 2 in-lb
10-32 UNF screw
35 in-lb
+/- 5 in-lb
6-32 UNC screw
12 in-lb
+/- 2 in-lb
Fuse block lugs
45 in-lb
+/- 2 in-lb
Field wiring lugs
50 in-lb
+/- 2 in-lb
Din-rail mounted terminal block
lugs
12 in-lb
+/- 2 in-lb
Contactor lugs
50 in-lb
+/- 2 in-lb
Ground bar lugs
35 in-lb
+/- 2 in-lb
M3 x 0.5 screw
12 in-lb
+/- 2 in-lb
#8 thread cutting screw
30 in-ib
+/- 2 in-lb
3/4" cable strain relief fitting
Hand-Tight + 1/4 turn
N/A