7
Installation
This chapter provides information on how to install the camera and adjust camera
angle and focus.
To install the camera you will need to prepare the mounting surface, make cable
connections, and mount the camera.
Cable connection
To make cable connections, do the following:
1. Connect a coaxial cable from the camera’s BNC connector to a CCTV monitor or
video recording device.
2. Connect a 12 VDC or 24 VAC power supply to the power input. The label on the
camera gives the following information:
Red cable.
Power in.
Black cable.
Power in.
White cable.
Video out.
Black cable.
Video ground.
Note:
For AC24V or DC12V, Black or Red may be used for ground.
Camera installation
To install the camera, attach the camera to the mounting surface using the
appropriate fasteners.
Angle adjustment
To adjust the horizontal angle of the platform up to 180 degrees, turn the platform
(Figure 4 on page 8).
To adjust the horizontal angle of the rotor up to 350 degrees, turn the rotor on the
platform (Figure 4 on page 8).
To adjust the vertical angle of the platform up to 90 degrees, turn the platform
(Figure 4 on page 8).