9
Ballast System—
All Ultra
★
★
★
★
★
Sport floodlights feature the new
compact GE Accuwatt
TM
ballast system in which the ballast is
direct mounted to the aluminum housing with a thermal wedge
for optimum heat transfer.
GE Accuwatt
TM
2000, 1500 and 1000 watt auto-regulator circuits
are designed to start and stabilize their respective double-ended
metal halide lamps at their design center.
Ballast dielectric material is rated for a 200 degree C maximum
operating temperature.
Every ballast undergoes a 2500 volt RMS “High Pot” and a
10KV “til” test in accordance with ANSI C82.4, C82.6 and C92.1
specifications. The ballast circuits are also designed to sustain a
nominal lamp over a line voltage dip of 50% for up to four
seconds when operating at nominal line voltage according to
ANSI specification C82.6.
Ultra
✭
Sport
TM
Floodlight
e
Optional System 2
TM
Bi-Level Controls—
The choice of
high/low two-level lighting is also available. System 2 Bi-Level
controls utilize a 15 volt AC signal that is hard wired to the
floodlight to switch capacitance and change wattage.
The 2000/1500 watt and 1500/1000 watt system choices are
available for separate game time and practice light levels.
The ballast circuit will reliably start and stabilize a
nominal lamp in ambient temperatures down to -29
degrees C. The unit is rated for operation in up to
40 degree C ambient temperatures.*
Ballast Maintenance
—
Electrical access is
achieved from the rear of the fixture without any
adjustment to the aiming required. The rear
housing cover is held in place by four captive
corrosion-resistant cad-polymer coated screws.
Optional Instant Hot Restart—
The
Ultra
★
★
★
★
★
Sport floodlight can be ordered with a new
optional instant hot restart feature. After a
momentary power interruption or line voltage dip
which causes the lamp to extinguish, a 34KV hot
restart circuit will restart the lamp within two
seconds of re-application of power.
% Allow-
able Line
Line
Power
Line
% Allow-
Line
Voltage
Operating
Line
Factor
Starting
able Line
Watts
Volts
Variation
Amperes
Watts %
Amperes
Voltage Dip
2000
208
11.2
2125
10.0
*25°C
240
9.5
2115
8.5
Max
277
8.3
2115
7.2
Ambient 347
±10
6.6
2122 90+
5.6
50
480
4.8
2132
4.4
1500
120
14.4
1630
11.2
*40°C
208
8.5
1630
6.9
Max
240
7.3
1630
5.6
Ambient 277
±10
6.3
1630 90+
4.7
50
347
4.8
1620
3.9
480
3.7
1630
2.8
1000
120
9.0
1080
6.6
*40°C
208
5.4
1070
4.1
Max
240
±
4.8
1080 90+
3.5
50
Ambient 237
4.1
1080
2.9
347
3.6
1070
2.9
480
2.6
1088
1.8
NOTE: For 50Hz voltages, contact factory.