background image

Step 6

Connect power cable to suitable supply in accord-

ance with all applicable codes.

A . Insert the lamp terminal into the

socket terminal (a) at both ends of the
lamp and torque screws to 20 in. lbs.

B . Slide the lamp ends into the sockets.

LAMP REPLACEMENT

C . Latch the lamp retainers (c).
D . Close and rebolt the relamping door.

Tighten bolts to 50 in. lbs. torque.

Caution: Do not touch quartz tube lamp with bare

hands! If lamp is handled, finger prints, grease or oils

should be removed from the lamp with isopropyl alcohol.

This will remove material which cause whitish spotting

and premature lamp failure. Dry lamp carefully with

cotton or clean cloth.

PERIODIC CLEANING WHEN RELAMPING:

INTERNAL:

 Should the internal reflector system require cleaning,

use only non-abrasive, neutral (pH 6-8) cleaner contain-

ing no chlorinated or aromatic hydrocarbons.

Rinse clean and wipe dry.

EXTERNAL:

 Clean front glass with a mild soap and water solution,

rinse clean and wipe dry.

NOTICE:

 Drain holes are provided in the proper

locations for customary mounting positions. If

floodlight is to be aimed up above the horizontal,

it is necessary to punch out the two knockouts in

the rear ballast cover and plug the three front

housing drain holes with a suitable material such

as silicone RTV.

INSTALLATION CLEANING:

DO NOT CLEAN INTERNAL OPTICAL SYSTEM

The Ultra

M

Sport floodlight has been specially re-

cleaned at the factory. Field cleaning of the internal

optical system during installation is not recommended.

EXTERNAL CLEANING

Initial cleaning of the outside of the glass lens may

be required to ensure optimum optical efficiency.

Clean front glass with a mild soap and water

solution rinse clean and wipe dry.

CLEANING INSTRUCTIONS AND CAUTIONS

After positioning luminaire, tighten all mounting

hardware.

Step 5

Optical Sight:
A . Rotate sight into vertical

position.

B . Align the reference

mark of top of reflector

flange with notch in

sight for proper aiming.

Base Sight
A. Rotate front and back

sight into vertical

position.

B. Align the two sighting

holes for proper aiming.

Step 4 — LUMINAIRE AIMING

Two sighting systems are provided for your convenience.

Use the sight system which is most easily accessed.

CAUTION

Risk of burn

Allow lamp/fixture to cool before

handling

REMOTE BALLAST MOUNTING

See below illustration for bolt spacing and bracket

minimum spacing.

Reviews: