background image

GEH-5736F

Ultra

 

 

Sport

TM

 Floodlight

INSTRUCTIONS

WARNING

Risk of electric shock

Turn power off before servicing

see instructions

NOTE: 

Make all electrical connections in accor-

dance with the National Electrical Code and any

applicable local code requirements.

NOTE:

 This luminaire is equipped with a safety

circuit to prevent lamp operation if the reflector

lens is broken. 

Complete optical assembly must

be replaced if the reflector lens is broken.

This luminaire is shipped with the lamp 

installed

.

This luminaire is designed for use in outdoor applica-

tions and should not be used in areas of limited ventila-

tion or high ambient temperature enclosures unless

otherwise stated on nameplate. Install and maintain it

according to the following recommendations.

NOTE: 

Connect ground lead to the green lead,

green ground screw on housing or terminal block

provided.
Replace power fuses only with fuses of the same

type and ratings.

CAUTION

Unit will fall if not installed properly

Follow installation instructions

NOTE:

 Verify that supply voltage is correct by

comparing it to nameplate.
Do not place combustible materials within 7 feet

(2 meters) of the front of the reflector lens.

Step 1 — POWER CABLE INSTALLATION

A . Disconnect Power
B . Remove Cover (a)
C . Loosen clamp (b)

Insert cable thru

clamp and grommet

D . Splice leads (c)

to power cable

E . Tighten clamp (b)
F . Replace cover (a)

 NOTE:

 Use 9/16 OD-

cable only.
3 conductor AWG #14

SEO 105C cable

is recommended.

Step 2 — LUMINAIRE MOUNTING

READ THOROUGHLY BEFORE INSTALLING

WARNING

Risk of fire

Keep combustible materials away

from lens – see instructions

Use lamps specified on nameplate

Step 3

g

GE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company.
© 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com

1

6 9 4 3 5 3 3

-

-

-

- 8 8 8

g

GE
Lighting Solutions

These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation
or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be