3. Parallel Data Input
- 5 -
3-2. Data input mode selection and signal specifications
The following three methods can be used for the parallel input data input method.
1) 16-bit with strobe
2) 8-bit multiplexed with strobe
3) 16-bit sample
These methods are selected with parameter No. C32-0.
(1) 16-bit with strobe (C32-0 = 1)
The 16-bit data (D0 to 15) is loaded with the rising edge of the strobe (STB).
D 0 ~ D 1 5
S T B
O F F
O N
D a ta 0
D a ta 1
D a ta 2
ts
th
tcy
D a ta 0
D a ta 1
tw
td s
In te rna l da ta
Fig. 3-2 16-bit with strobe time chart
(2) 8-bit multiplexed with strobe (C32-0 = 2)
The 16-bit data is divided into the low-order 8-bit and high-order 8-bit with the LSB signal, and
each is loaded with the rising edge of the strobe (STB).
D 0 ~ D 7
S T B
O F F
O N
D ata 0 (high-order)
D ata 1 (lo w -o rde r)
D ata 2 (high-order)
ts
th
tcy
D a ta 0
D a ta 1
tw
td s
In te rna l da ta
L S B
O F F
O N
Fig. 3-3 8-bit multiplexed with strobe time chart