ES-699 Rev U
Page 9 of 17
(IEC)
IECEx
{IEC Logo}
Ex ia IIC
T6
{Intrinsically Safe}
IECEx FMG 07.0007x
{CertificateNumber}
7.3
Operating Ranges
7.3.1
Temp:
-40°C to +85°C
7.3.2
Voltage:
30 Volts
7.3.3
Pressure:
80 psig (0.55 Mpa)
7.3.4
Current:
4-20mA
7.4
Enclosure Type:
“Type 4X
-
IP66”
7.5
Temperature Class:
“T6 Ta=60°C, T5 Ta=75°C, T4 Ta=85°C”
7.6
Notes Related to Intrinsic Safety
1)
“
INTRINISICALLY SAFE WHEN INSTALLED INSTALL Per ES-
699”
2)
“Supply Connection Wiring Rated for 5ºC Above Max Ambient”
3)
“
PERMANENTLY MARK THE PROTECTION TYPE
CHOSEN. ONCE THE TYPE HAS BEEN MARKED, IT CAN NOT
BE CHANGED”
7.7
Model Code:
“
SVI2-1bcdefg4
”
(see section 3 above for explanation)
7.8
Serial Number:
“SN
-nny
ywwnnnn”